Products
Filters
1032738 - PTTB 2,5-2DIO/UL-O/UR-O/U-OG/O-GN - Component terminal block (Qty. 50)
Phoenix ContactComponent terminal block, The max. current is determined by the diode. Installed: Diode 1N 4007, reverse voltage: 1300 V, maximum continuous curren...
View full details1032830 - MC 1,5/ 4-ST1-5,08 BD:L8-L5 - PCB connector
Phoenix ContactPCB connector, nominal cross section: 1.5 mm², color: green, nominal current: 8 A, rated voltage (III/2): 320 V, contact surface: Tin, type of cont...
View full details1032903 - MC 1,5/ 4-ST1-5,08 BD:G-W1 - PCB connector
Phoenix ContactPCB connector, nominal cross section: 1.5 mm², color: green, nominal current: 8 A, rated voltage (III/2): 320 V, contact surface: Tin, type of cont...
View full details1032905 - MC 1,5/ 3-ST1-5,08 BD:3N-2N - PCB connector
Phoenix ContactPCB connector, nominal cross section: 1.5 mm², color: green, nominal current: 8 A, rated voltage (III/2): 320 V, contact surface: Tin, type of cont...
View full details1032905 - MC 1,5/ 3-ST1-5,08 BD:3N-2N - PCB connector
Phoenix ContactPCB connector, nominal cross section: 1.5 mm², color: green, nominal current: 8 A, rated voltage (III/2): 320 V, contact surface: Tin, type of cont...
View full details1032910 - MC 1,5/ 3-ST1-5,08 BD:5N-6N - PCB connector
Phoenix ContactPCB connector, nominal cross section: 1.5 mm², color: green, nominal current: 8 A, rated voltage (III/2): 320 V, contact surface: Tin, type of cont...
View full details1032911 - MC 1,5/ 3-ST1-5,08 BD:SG-T- - PCB connector
Phoenix ContactPCB connector, nominal cross section: 1.5 mm², color: green, nominal current: 8 A, rated voltage (III/2): 320 V, contact surface: Tin, type of cont...
View full details1032914 - MC 1,5/ 3-ST1-5,08 BD:CH-A+ - PCB connector (Qty. 50)
Phoenix ContactPCB connector, nominal cross section: 1.5 mm², color: green, nominal current: 8 A, rated voltage (III/2): 320 V, contact surface: Tin, type of cont...
View full details1032916 - MC 1,5/ 3-ST1-5,08 BD:NC-C - PCB connector
Phoenix ContactPCB connector, nominal cross section: 1.5 mm², color: green, nominal current: 8 A, rated voltage (III/2): 320 V, contact surface: Tin, type of cont...
View full details1032920 - ELR 1-SC-230AC/600AC-20 - Solid-state contactor
Phoenix ContactSingle-phase solid-state contactor, input voltage: 230 V AC, output current: 20 A, zero voltage switch Specifications Item Value Country of Orig...
View full details1032922 - ELR 1-SC-230AC/600AC-30 - Solid-state contactor
Phoenix ContactSingle-phase solid-state contactor, input voltage: 230 V AC, output current: 30 A, zero voltage switch Specifications Item Value Country of Orig...
View full details1032926 - ELR 1-SC-24DC/600AC-50 - Solid-state contactor
Phoenix ContactSingle-phase solid-state contactor, input voltage: 24 V DC, output current: 50 A, zero voltage switch Specifications Item Value Country of Origi...
View full details1032996 - FA MCR-D-RM - DIN rail mounting frame
Phoenix ContactThe DIN rail mounting frame can be used to mount a display on a DIN rail, e.g., in the control cabinet. The DIN rail mounting frame can be used wit...
View full details1033120 - PTSA 1,5/ 5-3,5-Z MC OG/YE/BK - PCB terminal block
Phoenix ContactPCB terminal block, nominal current: 8 A, rated voltage (III/2): 400 V, nominal cross section: 1.5 mm², number of potentials: 5, number of rows: 1,...
View full details1033201 - MINI MCR-2-SPS-24-15-PT - Constant voltage source
Phoenix ContactConstant voltage source with pluggable connection technology for the generation of a highly precise constant voltage of 15 V and for the supply of ...
View full details1033341 - BC-508X14- 7 GN - PCB terminal block
Phoenix ContactPCB terminal block, nominal current: 13.5 A, rated voltage (III/2): 400 V, nominal cross section: 1.5 mm², number of potentials: 7, number of rows:...
View full details1033385 - SPT 2,5/ 2-V-5,0 BD:PE-PE - PCB terminal block
Phoenix ContactPCB terminal block, nominal current: 24 A, rated voltage (III/2): 400 V, nominal cross section: 2.5 mm², number of potentials: 2, number of rows: 1...
View full details1033388 - SPT 1,5/ 4-V-3,5 BD:3-6 - PCB terminal block
Phoenix ContactPCB terminal block, nominal current: 17.5 A, rated voltage (III/2): 200 V, nominal cross section: 1.5 mm², number of potentials: 4, number of rows:...
View full details1033485 - PACT RCP-4000A-1A-D190-3M-UV - Current transformer
Phoenix ContactSet consisting of one 1 A measuring transducer and one UV-resistant Rogowski coil with signal line. Length of Rogowski coil: 600 mm, diameter: 190 ...
View full details1033604 - ZFKDSA 1,5C-5,0- 4-EXPROFINET2 - PCB terminal block (Qty. 50)
Phoenix ContactPCB terminal block, nominal current: 16 A, nominal cross section: 1.5 mm², number of potentials: 4, number of rows: 1, number of positions per row:...
View full details1033785 - PTC 2,5-MT BU - Knife disconnect terminal block
Phoenix ContactKnife disconnect terminal block, nom. voltage: 400 V, nominal current: 20 A, 1 level, connection method: Push-in connection, Rated cross section: 2...
View full details1034213 - HC-B24/10-ADP-SS - Adapter plate
Phoenix ContactAdapter plate, type: B24 to B10 Specifications Item Value Country of Origin Germany No Links Available.
1034440 - PV-FT-CM-C-2,5-130-RD-FE10 - Device connector front mounting (Qty. 50)
Phoenix ContactPanel feed-through, Range of articles: Sunclix, Device connector front mounting, housing material: PPE, color: black, number of positions: 1, min. ...
View full details1034442 - PV-FT-CF-C-2,5-130-BU-FE10 - Device connector front mounting
Phoenix ContactPanel feed-through, Range of articles: Sunclix, Device connector front mounting, housing material: PPE, color: black, number of positions: 1, min. ...
View full details