Skip to content

1SDA070784R1 - E1.2B 1000 Ekip Touch LI 3p F F

by ABB
Original price $3,002.93 - Original price $3,002.93
Original price
$3,002.93
$3,002.93 - $3,002.93
Current price $3,002.93

C.BREAKER SACE EMAX2 E1.2B 1000 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP/TOUCH-LI R 1000 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED



ABB EcoSolutions
Item Value
ABB EcoSolutions Yes

Circular Value
Item Value
Circular Design Principles Recyclability Rate Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Conflict Minerals Reporting Template (CMRT) 9AKK108467A5658
End of Life Instructions 9AKK108468A2360
Group Waste to Landfill Target UL 2799 Zero Waste To Landfill Validation available
Toxic Substances Control Act - TSCA 9AKK108467A8326

Eco Transparency
Item Value
Environmental Product Declaration - EPD 9AKK108468A1900 9AKK108468A3028

Environmental
Item Value
Environmental Information 9AKK10103A1038 9AKK108467A6707
REACH Declaration 9AKK108466A1425
RoHS Information 9AKK108466A1424
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP 5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy (IT)

Ordering
Item Value
Order Code US and Canada Z1BQEGBD000A000000XX
Minimum Order Quantity 1 piece
Customs Tariff Number 85362090

Dimensions
Item Value
Product Net Width 210 mm
Product Net Height 296 mm
Product Net Depth / Length 183 mm
Product Net Weight 14 kg

Additional Information
Item Value
Current Type AC
Electrical Durability Ue =< 440 V 8000 cycleUe = 500 ... 690 V 8000 cycle30 cycles per hour
Mechanical Durability 20000 cycle60 cycles per hour
Number of Poles 3
Power Loss 78 W
Product Main Type SACE Emax 2
Product Name Air Circuit Breaker
Product Type Air Circuit Breaker
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) 100 %
Rated Current (In) 1000 A
Rated Voltage (Ur) 690 V
Rated Impulse Withstand Voltage (Uimp) acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui) AC 1000 V
Rated Operational Voltage 690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics) (220 V AC) 42 kA(230 V AC) 42 kA(380 V AC) 42 kA(400 V AC) 42 kA(415 V AC) 42 kA(440 V AC) 42 kA(500 V AC) 42 kA(660 V AC) 42 kA(690 V AC) 42 kA
Rated Short-time Withstand Current Low Voltage (Icw) for 1 s 42 kAfor 3 s 24 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (400 V AC) 42 kA(415 V AC) 42 kA(440 V AC) 42 kA(500 V AC) 42 kA(525 V AC) 42 kA(690 V AC) 42 kA
Rated Uninterrupted Current (Iu) 1000 A
Recommended Screw Driver Main Circuit M10
Release Ekip Touch LI
Release Type EL
Short-Circuit Performance Level B
Standards IEC
Sub-type E1.2
Terminal Connection Type Front
Terminal Type Bolt
Tightening Torque 45 N·m
Version F
CAD Dimensional Drawing 1SDH001252R0001

Classifications
Item Value
ETIM 9 EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC) 4926 >> Air circuit breakers
Object Classification Code Q
WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)
eClass V11.1 : 27370409

No Links Available.