Power Distribution
Filters
140G-M5F4-D80 - 140G - Molded Case Circuit Breaker, M frame, 50 kA, T/M - Thermal Magnetic, 4 Poles, Rated Current 800 A
Allen-BradleyMolded Case Ckt-BKR, 800A M Frame, T/M - Adjst Thrm / Adjst Mgntc, 4 Poles, 800A, 80 Percent MCCB, No Bus Bar Mounting, NONE, None, NONE, NoneNo Sp...
View full details1492-SPM3D005 - Bulletin 1492-SPM Supplementary Protectors, 3-Pole, Trip Curve D, 0.5 A, No Neutral
Allen-BradleySupplementary Protectors, 3 Pole Configuration, Trip Curve D, 0.5ANo Specifications Available. No Links Available.
3VA9471-0WJ30 - BREAKER 3VA6 600 REAR SHIELD LONG 3P 1PC
SiemensBREAKER 3VA Insulating plate FOR 3VA63 at 400A and 3VA64 at 600A FOR 3 POLE BREAKERS PLASTIC Rear extended Specifications Item Value Country of ...
View full details1489-M1D160 - Bulletin 1489 Miniature Circuit Breaker, Standard configuration, AC, 1 Pole Configuration, Trip Curve D, UL/CSA Max. Voltage: 240V AC, 48V DC, IEC/EN Max. Voltage: 230V AC,16 A
Allen-Bradley1489-M Miniature Circuit Breaker, Standard configuration, AC, UL/CSA Max. Voltage: 240V AC, 48V DC, IEC/EN Max. Voltage: 230V AC, 1Pole Configurati...
View full details1492-MCEA115 - 1492-MC Circuit Breaker, 1492 Miniature Circuit Breaker, 120 V AC, Ground Fault Equipment Protector (GFEP), Panel mounting, 10 kA, 1 Pole, 15 Amps, Standard Terminal, None
Allen-BradleyMiniature Circuit Breaker, Ground Fault Equipment Protector (GFEP), Panel mounting, 10 Ka, Standard Terminal, None, 120/240V AC, 1pole, 15 AmpsNo S...
View full detailsAB1GD - Marker, Linergy TR, clip-in marker type, character D, symbolic, strip of 10
Schneider ElectricNo Description Available.No Specifications Available. No Links Available.
140G-KC0F3-D40-SJ-AA - 140G - Molded Case Circuit Breaker, KC frame (current limiting), 100 kA, T/M - Thermal Magnetic, 3 Poles, Rated Current 400 A, Shunt Trip 24...30V AC/DC, 1 NO/NC AUX + Alarm, 250V
Allen-BradleyMolded Case Ckt-BKR, 400A K Frame Current Limiting, 100 kA at 480V, T/M - Adjst Thrm / Adjst Mgntc, 3 Poles, 400A, 80 Percent MCCB, No BusBar Mount...
View full details1489-AMRA3 - 1489-M Miniature Circuit Breaker Accessories, 1 C.O. Auxiliary Contact
Allen-BradleyAuxiliary Contact, 1489 Miniature Circuit Breaker Accessory, 1 C.O., UL and IEC rated, right mountNo Specifications Available. No Links Available.
140G-MTI3-D80 - Molded Case Circuit Breaker Trip Unit, 800A, M - Frame, Electronic LSIG - Long & Short Time, High Instantaneous, Ground Fault, Rated Current 800 A
Allen-BradleyMolded Case Circuit Breaker Trip Unit, 800A Frame, 800A, LSIG, 3 PoleNo Specifications Available. No Links Available.
3VA9224-0JJ13 - BRKR 3VA2 250A LUG 4P 1W LARGE
SiemensNo Description Available. Specifications Item Value EF013236 true Country of Origin US EF013237 false Type of accessory Connection techniq...
View full details140G-J6F3-D25-BA - 140G - Molded Case Circuit Breaker, J frame, 65 kA, T/M - Thermal Magnetic, 3 Poles, Rated Current 250 A, 2 NO/NC AUX + Alarm, 250V
Allen-BradleyMolded Case Ckt-BKR, 250A J Frame, 65 kA at 480V, T/M - Adjst Thrm / Adjst Mgntc, 3 Poles, 250A, 80 Percent MCCB, No Bus Bar Mounting, NONE, 250V A...
View full details3VA5330-6EF41-0AA0 - BRKR 3VA53 4P 300A 65KA ATAM
SiemensOEZ-LK1496-ST400 Specifications Item Value Country of Origin CZ Number of poles 4 Rated voltage 690 V Motor drive optional true Motor dr...
View full details1492-D2C030 - 1492-D Miniature Circuit Breakers, Trip Curve C, 2-Pole, 3 A
Allen-BradleyMiniature Circuit Breakers, 2 Pole Configuration, Trip Curve C, 3ANo Specifications Available. No Links Available.
1492-SPM1D080-N - Bulletin 1492-SPM Supplementary Protectors, 1-Pole, Trip Curve D, 8 A, +Neutral Option
Allen-BradleySupplementary Protectors, 1 Pole Configuration, Trip Curve D, 8A, +Neutral OptionNo Specifications Available. No Links Available.
140G-J3C3-C50-SJ - 140G - Molded Case Circuit Breaker, J frame, 35 kA, T/M - Thermal Magnetic, 3 Poles, Rated Current 50 A, Shunt Trip 24...30V AC/DC
Allen-BradleyMolded Case Ckt-BKR, 250A J Frame, 35 kA at 480V, T/M - Fixed Thrm / Fixed Mgntc, 3 Poles, 50A, 80 Percent MCCB, No Bus Bar Mounting, None, 24…30V ...
View full details3VA9503-0JB32 - BRKR 3VA1/2 1250A 3P LUG 3W
SiemensSIEMENS LOW VOLTAGE 3VA CIRCUIT BREAKER ACCESSORY. 3-PIECE ALUMINUM BODY 3-CONDUCTOR LUG TERMINAL - WIRE SIZE: 120 - 185 SQMM.FOR (800-1250A 3VA1/2...
View full detailsM9F23232 - Miniature circuit breaker (MCB), Multi9 C60SP, 2P, 32A, D curve, 10kA (UL1077), 10kA (IEC/EN 60947-2)
Schneider ElectricThis Multi9 C60SP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 32A rated current and D trip...
View full details4983-DS120-802 - 4983 Surge and Filter Protection, Din Rail Mount, UL 1449, 120V, 80kA, 2 Pole Configuration
Allen-BradleySURGE PROTECTIVE DEVICE, 120VAC, 80kA, 2-POLENo Specifications Available. No Links Available.
M9F43305 - Miniature circuit breaker (MCB), Multi9 C60BP, 3P, 5A, D curve, 10kA (UL489), 10kA (IEC/EN 60947-2)
Schneider ElectricThis Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 3P circuit breaker with 3 protected poles, 5A rated current and D tripp...
View full details3VA5220-5EC36-1AA0 - BRKR 3VA52 3P 200A 35KA FTAM NAV AL
SiemensOEZ-LK1496-ST250 Specifications Item Value Number of poles 3 Country of Origin CZ Rated voltage 690 V Motor drive optional true Motor dr...
View full details140G-H3C4-C70 - 140G - Molded Case Circuit Breaker, H frame, 35 kA, T/M - Thermal Magnetic, 4 Poles, Rated Current 70 A
Allen-BradleyMolded Case Ckt-BKR, 125A H Frame, 35 kA at 480V, T/M - Fixed Thrm / Fixed Mgntc, 4 Poles, 70A, 80 Percent MCCB, No Bus Bar Mounting, NONE, None, N...
View full details3VA4170-4ED14-0AA0 - BRKR 3VA41 1P 70A 25KA FTFM LD LUG
SiemensSIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA41 FRAME WITH STANDARD (CLASS S) BREAKING CAPACITY. 70...
View full details1SDA054532R1 - T5V400 TMA400-4000 4pFFC1150VAC/DC N100%
ABBC.BREAKER TMAX T5V 400 1150V AC-1000V DC FIXED FOUR-POLE WITH FRONT TERMINALS FOR CABLE Cu AND THERMOMAGNETIC RELEASE TMA R 400-4000 A FULLY RATED ...
View full details1SDA066890R1 - KIT ES XT1 4pcs
ABBEXTENDED FRONT TERMINALS DISTANCE 4pcs XT1 Circular Value Item Value Conflict Minerals Reporting Template (CMRT) 9AKK108467A5658 Toxic Substan...
View full details