1SAM461000R1017 - MO165-65 Manual Motor Starter Magnetic Only 65 A

by ABB
Original price $208.90 - Original price $208.90
Original price
$208.90
$208.90 - $208.90
Current price $208.90

The MO165 manual motor starter magnetic only is a compact and powerful range for motor protection up to 45 kW (400 V) in width of 55 mm. The devices are used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity up to 100 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starters magnetic only are suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars and power in-feed blocks are available as accessory.



Ordering
Item Value
Minimum Order Quantity 1 piece
Customs Tariff Number 85362090

Dimensions
Item Value
Product Net Width 55 mm
Product Net Height 142.65 mm
Product Net Depth / Length 122.1 mm
Product Net Weight 0.98 kg

Technical
Item Value
Rated Service Short-Circuit Breaking Capacity (Ics) (230 V AC) 30 kA(250 V DC) 3 Poles in Series 100 kA(400 V AC) 30 kA(440 V AC) 30 kA(500 V AC) 20 kA(690 V AC) 6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (230 V AC) 50 kA(250 V DC) 100 kA(400 V AC) 50 kA(440 V AC) 45 kA(500 V AC) 20 kA(690 V AC) 8 kA
Rated Instantaneous Short-Circuit Current Setting (Ii) 975 A
Setting Range None
Rated Operational Power AC-3 (Pe) (400 V) Three Phase 30 kW
Rated Operational Power AC-3e (Pe) (400 V) Three Phase 30 kW
Rated Operational Voltage Main Circuit 690 V ACMain Circuit 250 V DC
Rated Operational Current (Ie) 65 A
Rated Operational Current AC-3 (Ie) 65 A
Rated Operational Current AC-3e (Ie) 65 A
Rated Operational Current DC-5 (Ie) 65 A
Rated Frequency (f) Main Circuit 50 HzMain Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp) Main Circuit 8 kV
Rated Insulation Voltage (Ui) 1000 V
Power Loss 8.03 W
Number of Poles 3
Conventional Free-air Thermal Current (Ith) Main Circuit 65 A
Degree of Protection Housing IP20Main Circuit Terminals IP10
Pollution Degree 3
Electrical Durability 25000 cycle
Mechanical Durability 50000 cycle
Terminal Type Screw Terminals
Connecting Capacity Main Circuit Flexible with Ferrule 1/2x 1 ... 35 mm²Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²Flexible 1/2x 1 ... 35 mm²Rigid 1/2x 1 ... 4 mm²Solid 1/2x 1 ... 4 mm²Stranded 1/2x 1 ... 50 mm²
Tightening Torque Main Circuit 4 N·m
Wire Stripping Length Main Circuit 16 mm
Recommended Screw Driver Pozidriv 2
Mounting Position 1 ... 6
Mounting on DIN Rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mmElectrical Conductive Board, Horizontal - Up to 400 V 0 mmElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mmElectrical Conductive Board, Vertical 75 mmOther Device Same Type, Horizontal 0 mmOther Device Same Type, Vertical 150 mm
Actuator Type Rotary Handle
Contact Position Indication ON / OFF / TRIP
Standards CSA 22.2 No. 14IEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1UL 60947-4-1
Remarks For overload protection of the motors, an appropriate thermal or electronic overload relays must be used

Technical UL/CSA
Item Value
Short-Circuit Current Rating (SCCR) Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kAManual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Maximum Operating Voltage UL/CSA Main Circuit 600 V AC
Horsepower Rating UL/CSA (200 V AC) Three Phase 20 Hp(208 V AC) Three Phase 20 Hp(220 ... 240 V AC) Three Phase 20 Hp(440 ... 480 V AC) Three Phase 50 Hp(550 ... 600 V AC) Three Phase 60 Hp
Full Load Amps Motor Use (200 V AC) Three Phase 62.1 A(208 V AC) Three Phase 59.4 A(220 ... 240 V AC) Three Phase 54 A(440 ... 480 V AC) Three Phase 65 A(550 ... 600 V AC) Three Phase 62 A
Locked Rotor Amps (200 V AC) Three Phase 334 A(208 V AC) Three Phase 321 A(220 ... 240 V AC) Three Phase 290 A(440 ... 480 V AC) Three Phase 363 A(550 ... 600 V AC) Three Phase 348 A
General Use Rating UL/CSA (600 V AC) 65 A
Connecting Capacity Main Circuit UL/CSA Flexible 1/2x 16-0 AWGStranded 1/2x 16-0 AWG
Tightening Torque UL/CSA Main Circuit 35 in·lb

Environmental
Item Value
Ambient Air Temperature Operation -25 ... +60 °COperation Compensated -25 ... +60 °CStorage -50 ... +80 °C
Ambient Air Temperature Compensation No
Maximum Operating Altitude Permissible 2000 m
Resistance to Shock acc. to IEC 60068-2-27 11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6 mounted on DIN-rail: 4g / 3 ...150 Hzmounted on mounting plate: 5g / 3 ... 150 Hz5g / 3 ... 150 Hz
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Classifications
Item Value
Object Classification Code F
ETIM 5 EC000074 - Motor protective circuit-breaker
eClass V11.0 : 27370401
IDEA Granular Category Code (IGCC) 4731 >> Manual Starters
E-Number (Finland) 3707297
E-Number (Sweden) 3110144