Skip to content

1SAM250000R1009 - MS116-6.3 Manual Motor Starter 4.0 ... 6.3 A

by ABB
Original price $37.25 - Original price $37.25
Original price
$37.25
$37.25 - $37.25
Current price $37.25

The MS116-6.3 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 6.3 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.



Ordering
Item Value
Minimum Order Quantity 1 piece
Customs Tariff Number 85362010

Dimensions
Item Value
Product Net Width 45 mm
Product Net Height 90 mm
Product Net Depth / Length 85.6 mm
Product Net Weight 0.265 kg

Technical
Item Value
Rated Service Short-Circuit Breaking Capacity (Ics) (230 V AC) 50 kA(400 V AC) 50 kA(440 V AC) 6 kA(500 V AC) 6 kA(690 V AC) 2 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (230 V AC) 75 kA(400 V AC) 75 kA(440 V AC) 18 kA(500 V AC) 15 kA(690 V AC) 3 kA
Rated Instantaneous Short-Circuit Current Setting (Ii) 78.8 A
Setting Range 4.0 ... 6.3 A
Rated Operational Power AC-3 (Pe) (400 V) Three Phase 2.2 kW
Rated Operational Power AC-3e (Pe) (400 V) Three Phase 2.2 kW
Rated Operational Voltage Main Circuit 690 V AC
Rated Operational Current (Ie) 6.3 A
Rated Operational Current AC-3 (Ie) 6.3 A
Rated Operational Current AC-3e (Ie) 6.3 A
Rated Frequency (f) Main Circuit 50 HzMain Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp) Main Circuit 6 kV
Rated Insulation Voltage (Ui) 690 V
Power Loss at Rated Operating Conditions per Pole 0.7 ... 1.8 W
Number of Poles 3
Conventional Free-air Thermal Current (Ith) Main Circuit 6.3 A
Degree of Protection Housing IP20Main Circuit Terminals IP10
Pollution Degree 3
Electrical Durability 100000 cycle
Mechanical Durability 100000 cycle
Terminal Type Screw Terminals
Connecting Capacity Main Circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²Flexible 1/2x 0.75 ... 2.5 mm²Rigid 1/2x 1 ... 4 mm²
Tightening Torque Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length Main Circuit 9 mm
Recommended Screw Driver Pozidriv 2
Mounting Position any1 ... 6
Mounting on DIN Rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance Electrical Conductive Board, Horizontal - Up to 400 V 0 mmElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mmElectrical Conductive Board, Vertical 75 mmOther Device Same Type, Horizontal 0 mmOther Device Same Type, Vertical 150 mm
Actuator Type Rotary Handle
Contact Position Indication ON / OFF
Standards IEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1UL 60947-1UL 60947-4-1

Technical UL/CSA
Item Value
Short-Circuit Current Rating (SCCR) Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 18 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 18 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Maximum Operating Voltage UL/CSA Main Circuit 600 V AC
Horsepower Rating UL/CSA (200 V AC) Three Phase 1 Hp(208 V AC) Three Phase 1 Hp(220 ... 240 V AC) Three Phase 1.5 Hp(440 ... 480 V AC) Three Phase 3 Hp(550 ... 600 V AC) Three Phase 5 Hp
Full Load Amps Motor Use (200 V AC) Three Phase 6.3 A(208 V AC) Three Phase 6.3 A(220 ... 240 V AC) Three Phase 6.3 A(440 ... 480 V AC) Three Phase 4.8 A(550 ... 600 V AC) Three Phase 6.1 A
Locked Rotor Amps (200 V AC) Three Phase 37.8 A(208 V AC) Three Phase 37.8 A(220 ... 240 V AC) Three Phase 37.8 A(440 ... 480 V AC) Three Phase 32 A(550 ... 600 V AC) Three Phase 36.8 A
General Use Rating UL/CSA (600 V AC) 6.3 A
Connecting Capacity Main Circuit UL/CSA Flexible 1/2x 16-12 AWGStranded 1/2x 16-12 AWG
Tightening Torque UL/CSA Main Circuit 10 in·lb

Environmental
Item Value
Ambient Air Temperature Around the Enclosure 0 ... +40 °COperation -25 ... +70 °COperation Compensated -25 ... +55 °CStorage -50 ... +80 °C
Ambient Air Temperature Compensation Yes
Maximum Operating Altitude Permissible 2000 m
Resistance to Shock acc. to IEC 60068-2-27 11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6 5g / 3 ... 150 Hz
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Classifications
Item Value
Object Classification Code F
ETIM 4 EC000074 - Motor protective circuit-breaker
ETIM 5 EC000074 - Motor protective circuit-breaker
eClass V11.0 : 27370401
IDEA Granular Category Code (IGCC) 4731 >> Manual Starters
E-Number (Finland) 3706009
E-Number (Sweden) 3111946

No Links Available.