SK827041-AF - EK550-40-11 110V 50Hz / 120V 60Hz Contactor
by ABB
Original price
$3,205.68
-
Original price
$3,205.68
Original price
$3,205.68
$3,205.68
-
$3,205.68
Current price
$3,205.68
A 4-pole Contactor suitable for Distribution and Rail way applications AC and DC switching. Operated with control voltage, versions from 24….690 AC, 50/60 Hz and 24-220 V DC
Item | Value |
---|---|
Minimum Order Quantity | 1 piece |
Customs Tariff Number | 85364900 |
Item | Value |
---|---|
Product Net Width | 270 mm |
Product Net Depth / Length | 225.5 mm |
Product Net Height | 272 mm |
Product Net Weight | 15.5 kg |
Item | Value |
---|---|
Number of Main Contacts NO | 4 |
Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 1 |
Number of Auxiliary Contacts NC | 1 |
Rated Operational Voltage | Main Circuit 1000 V |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 800 A |
Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 800 A(1000 V) 60 °C 650 A(1000 V) 70 °C 575 A(690 V) 40 °C 800 A(690 V) 55 °C 650 A(690 V) 60 °C 650 A(690 V) 70 °C 575 A |
Rated Operational Current AC-3 (Ie) | (440 V) 55 °C 550 A(500 V) 55 °C 550 A(690 V) 55 °C 550 A(1000 V) 55 °C 175 A(380 / 400 V) 55 °C 550 A(220 / 230 / 240 V) 55 °C 550 |
Rated Operational Power AC-3 (Pe) | (415 V) 315 kW(440 V) 315 kW(500 V) 400 kW(690 V) 500 kW(1000 V) 35 kW(380 / 400 V) 280 kW(220 / 230 / 240 V) 160 kW |
Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
Rated Making Capacity AC-3 | 10 x Ie AC-3 |
Short-Circuit Protective Devices | gG Type Fuses 800 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 5300 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 5500 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3700 A |
Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour(AC-2 / AC-4) 120 cycles per hour(AC-3) 300 cycles per hour |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) | 8 kV |
Mechanical Durability | 5 million |
Maximum Mechanical Switching Frequency | 3600 cycles per hour |
Coil Operating Limits | (acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C) |
Rated Control Circuit Voltage (Uc) | 50 Hz 110 V60 Hz 120 V |
Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 125 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 140 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 3500 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 4000 V·A |
Operate Time | Between Coil De-energization and NC Contact Closing 10 ... 20 msBetween Coil De-energization and NO Contact Opening 13 ... 23 msBetween Coil Energization and NC Contact Opening 25 ... 55 msBetween Coil Energization and NO Contact Closing 30 ... 60 ms |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
Connecting Terminals (delivered in open position) Main Poles | Flat type c/w screws and bolts |
Terminal Type | Main Circuit: Bars |
Item | Value |
---|---|
General Use Rating UL/CSA | (600 V AC) 540 A |
Item | Value |
---|---|
Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -50 ... 70 °C |
Maximum Operating Altitude Permissible | Without Derating 3000 m |
RoHS Status | Following EU Directive 2011/65/EU |
Item | Value |
---|---|
Object Classification Code | Q |
ETIM 4 | EC000066 - Magnet contactor, AC-switching |
ETIM 5 | EC000066 - Magnet contactor, AC-switching |
eClass | V11.0 : 27371003 |
IDEA Granular Category Code (IGCC) | 4755 >> Contactors |