6SL32101KE284AF1 - SINAMICS G120C PN 45.0KW FILA
by Siemens
Original price
$6,664.12
-
Original price
$6,664.12
Original price
$6,664.12
$6,664.12
-
$6,664.12
Current price
$6,664.12
SINAMICS G120C RATED POWER 45.0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI. 2DO. 1AI. 1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSD 472x 200x 237(HXWXD) EXTERNAL 24V
Item | Value |
---|---|
Country of Origin | DE |
Depth | 237 mm |
Width | 200 mm |
Height | 472 mm |
Mains voltage | 380 V |
With PC connection | true |
Max. output voltage | 480 V |
Number of phases input | 3 |
Number of phases output | 3 |
Number of digital inputs | 6 |
Max. output frequency | 550 Hz |
Number of analogue inputs | 1 |
Number of digital outputs | 2 |
Number of analogue outputs | 1 |
With optical interface | false |
Number of HW-interfaces USB | 1 |
Type of converter | U converter |
Degree of protection (IP) | IP20 |
Number of HW-interfaces other | 6 |
Number of interfaces PROFINET | 2 |
Nominal output current I2N | 82.5 A |
Number of HW-interfaces RS-232 | 1 |
Number of HW-interfaces RS-422 | 0 |
Number of HW-interfaces RS-485 | 0 |
Supporting protocol for ASI | false |
Supporting protocol for CAN | false |
Supporting protocol for KNX | false |
Supporting protocol for LON | false |
Number of HW-interfaces parallel | 0 |
4-quadrant operation possible | false |
Integrated breaking resistance | true |
Number of HW-interfaces serial TTY | 1 |
Supporting protocol for BACnet | false |
Supporting protocol for MODBUS | false |
Supporting protocol for SERCOS | false |
Supporting protocol for TCP/IP | false |
Supporting protocol for SUCONET | false |
Supporting protocol for INTERBUS | false |
Supporting protocol for PROFIBUS | false |
Supporting protocol for PROFIsafe | true |
Supporting protocol for DeviceNet | false |
Supporting protocol for EtherNet/IP | true |
Supporting protocol for PROFINET IO | true |
Supporting protocol for SafetyBUS p | false |
Supporting protocol for Data-Highway | false |
Supporting protocol for PROFINET CBA | false |
Relative symmetric net voltage tolerance | 10 % |
Application in industrial area permitted | true |
Number of HW-interfaces industrial Ethernet | 2 |
Relative symmetric net frequency tolerance | 5 % |
Supporting protocol for INTERBUS-Safety | false |
Supporting protocol for DeviceNet Safety | false |
Supporting protocol for other bus systems | true |
Supporting protocol for Foundation Fieldbus | false |
Max. output at linear load at rated output voltage | 37 kW |
Supporting protocol for AS-Interface Safety at Work | false |
Max. output at quadratic load at rated output voltage | 45 kW |
Application in domestic- and commercial area permitted | true |