Skip to content

1SFA896103R1100 - PSR3-600-11 Softstarter - 3.9 A - 208 ... 600 V AC

by ABB
Original price $193.69 - Original price $193.69
Original price
$193.69
$193.69 - $193.69
Current price $193.69

The softstarter PSR3-600-11 has a rated maximum operational current of 3 A with an operating voltage span from 208...600 V AC. The rated control voltage is 24 V AC/DC. PSR features a two-phase control soft start and stop through a voltage ramp. It has built-in bypass for easy installation and energy saving. A RUN signal is available from a relay output in NO (normally open state). The start/stop ramp and time is easy to set by three potentiometers on the front. PSR is often used in combination with a manual motor starter (MMS) from ABB, so mechanical connection kits are available. Another popular option is Fieldbus communication, which can be enabled by an external adaptor and a Fieldbus plug. The PSR range is our most compact softstarters with basic functionality and values. They are suitable for small three-phase motors with nominal currents from 3...105 A and can manage up to 100 starts per hour. Common applications are, for example, pumps, fans, compressors, and conveyors.



Ordering
Item Value
Minimum Order Quantity 1 piece
Customs Tariff Number 85371091

Dimensions
Item Value
Product Net Width 114 mm
Product Net Height 140 mm
Product Net Depth / Length 45 mm
Product Net Weight 0.4 kg

Technical
Item Value
Rated Operational Voltage 208 ... 600 V AC
Rated Control Supply Voltage (Us) 24 V AC/DC
Rated Control Circuit Voltage (Uc) 24 V DC
Rated Frequency (f) 50/60 HzMain Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe) (230 V) 0.75 kW(400 V) 1.5 kW(500 V) 2.2 kW
Rated Operational Current - In-Line Connection (Ie) 3.9 A
Service Factor Percentage 100 %
Overload Protection Recommended MS116 0.63 ... 4.00
Integrated Electronic Overload No
Adjustable Rated Motor Current Ie No
Starting Capacity at Maximum Rated Current Ie 4xIe for 6s
Ramp Time 0 ... 20 second [unit of time]1 ... 10 second [unit of time]
Initial Voltage During Start 40 ... 70 %
Step Down Voltage Special Ramp 100 ... 60 %
Current Limit Function No
Switch for Inside Delta Connection No
Run Signal Relay Yes
By-pass Signal Relay No
Fault Signal Relay No
Overload Signal Relay No
Signal Indication Completed Start Ramp (LED) Green
Signal Indication Ready to Start/Standby ON (LED) Green
Signal Indication Running R (LED) Green
Signal Indication Ramping Up/Down (LED) Green
Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time 10
Communication FiledBusPlug(Optional)
Degree of Protection IP20
Terminal Type Screw Terminals
Connecting Capacity Main Circuit Rigid 1/2 x 0.75 ... 2.5 mm²
Connecting Capacity Control Circuit 1 x 0.75 ... 2.52 x 0.75 ... 2.5 mm²Rigid 1/2 x 0.75 ... 2.5 mm²
Connecting Capacity Supply Circuit Rigid 1/2 x 0.75 ... 2.5 mm²
Tightening Torque Control Circuit 1 N·mMain Circuit 1 N·mSupply Circuit 1 N·m
Product Main Type PSR3
Function Soft start with voltage rampSoft stop with voltage ramp

Technical UL/CSA
Item Value
Maximum Operating Voltage UL/CSA Main Circuit 600 V
Tightening Torque UL/CSA Control Circuit 8.9 in·lbMain Circuit 8.9Supply Circuit 8.9 in·lb

Environmental
Item Value
Ambient Air Temperature Operation -25 ... +60 °CStorage -40 ... +70 °C
Degree of Protection IP20
RoHS Status Following EU Directive 2002/95/EC August 18, 2005 and amendment

Classifications
Item Value
Object Classification Code Q
ETIM 9 EC000640 - Soft starter
eClass V11.0 : 27370907
IDEA Granular Category Code (IGCC) 4740 >> Soft starter

No Links Available.