Skip to content

6SL32101KE123UF2 - SINAMICS G120C RATED POWER 0.75KW WITH 1

by Siemens
Original price $695.34 - Original price $695.34
Original price
$695.34
$695.34 - $695.34
Current price $695.34

SINAMICS g120c rated power 0,75KW with 150% overload for 3 sec 3AC380-480v +10/-20% 47-63HZ unfiltered i/o-interface 6di, 2do,1ai,1ao safe torque off integrated fieldbus PROFINET-pn protection IP20/ ul open type size fsaa 173x73x178(hxwxd) external 24v



Specifications
Item Value
Country of Origin GB
Width 73 mm
Depth 178 mm
Height 173 mm
Mains voltage 380 V
With PC connection true
Max. output voltage 480 V
Number of phases input 3
Number of phases output 3
Number of digital inputs 6
Max. output frequency 550 Hz
Number of analogue inputs 1
Number of digital outputs 2
Number of analogue outputs 1
With optical interface false
Number of HW-interfaces USB 1
Type of converter U converter
Degree of protection (IP) IP20
Nominal output current I2N 2.3 A
Number of HW-interfaces other 6
Number of interfaces PROFINET 2
Number of HW-interfaces RS-232 1
Number of HW-interfaces RS-422 0
Number of HW-interfaces RS-485 0
Supporting protocol for ASI false
Supporting protocol for CAN false
Supporting protocol for KNX false
Supporting protocol for LON false
Number of HW-interfaces parallel 0
4-quadrant operation possible false
Integrated breaking resistance true
Number of HW-interfaces serial TTY 1
Supporting protocol for BACnet false
Supporting protocol for MODBUS false
Supporting protocol for SERCOS false
Supporting protocol for TCP/IP false
Supporting protocol for SUCONET false
Supporting protocol for INTERBUS false
Supporting protocol for PROFIBUS false
Supporting protocol for PROFIsafe true
Supporting protocol for DeviceNet false
Supporting protocol for EtherNet/IP true
Supporting protocol for PROFINET IO true
Supporting protocol for SafetyBUS p false
Supporting protocol for Data-Highway false
Supporting protocol for PROFINET CBA false
Relative symmetric net voltage tolerance 10 %
Number of HW-interfaces industrial Ethernet 2
Relative symmetric net frequency tolerance 5 %
Supporting protocol for INTERBUS-Safety false
Application in industrial area permitted false
Supporting protocol for DeviceNet Safety false
Supporting protocol for other bus systems true
Supporting protocol for Foundation Fieldbus false
Max. output at linear load at rated output voltage 0.55 kW
Supporting protocol for AS-Interface Safety at Work false
Application in domestic- and commercial area permitted false
Max. output at quadratic load at rated output voltage 0.75 kW

No Links Available.