1SFL497025R6911 - GAF185-10-11 48-130V 50/60Hz / 48-130V DC Contactor
by ABB
Original price
$1,072.07
-
Original price
$1,072.07
Original price
$1,072.07
$1,072.07
-
$1,072.07
Current price
$1,072.07
A 3-pole Contactor suitable for DC-1 applications where all three poles must be connected in series in a 1-pole configuration up to max 1000 VDC. Operated with wide control voltage range 48-130 V, AC/DC
Item | Value |
---|---|
Minimum Order Quantity | 1 piece |
Customs Tariff Number | 85364900 |
Item | Value |
---|---|
Product Net Width | 111.5 mm |
Product Net Depth / Length | 160 mm |
Product Net Height | 196 mm |
Product Net Weight | 3 kg |
Item | Value |
---|---|
Number of Main Contacts NO | 1 |
Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 1 |
Number of Auxiliary Contacts NC | 1 |
Rated Operational Voltage | Main Circuit 1000 V |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 275 A |
Rated Operational Current DC-1 (Ie) | (1000 V) 3 Poles in Series, 40 °C 275 A(1000 V) 3 Poles in Series, 55 °C 250 A(1000 V) 3 Poles in Series, 70 °C 180 A(220 V) 3 Poles in Series, 40 °C 275 A(220 V) 3 Poles in Series, 55 °C 250 A(220 V) 3 Poles in Series, 70 °C 180 A(400 V) 3 Poles in Series, 40 °C 275 A(400 V) 3 Poles in Series, 55 °C 250 A(400 V) 3 Poles in Series, 70 °C 180 A(600 V) 3 Poles in Series, 40 °C 275 A(600 V) 3 Poles in Series, 55 °C 250 A(600 V) 3 Poles in Series, 70 °C 180 A |
Rated Insulation Voltage (Ui) | acc. to UL/CSA 1000 V |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
Mechanical Durability | 5 million |
Maximum Mechanical Switching Frequency | 300 cycles per hour |
Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
Rated Control Circuit Voltage (Uc) | 50 Hz 48 ... 130 V60 Hz 48 ... 130 VDC Operation 48 ... 130 V |
Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 2 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 430 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 430 V·APull-in at Max. Rated Control Circuit Voltage DC 500 V·A |
Connecting Capacity Main Circuit | Bar 24 mm²Rigid Al-Cable 25 ... 150 mm²Rigid Cu-Cable 6 ... 185 mm² |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm² |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
Terminal Type | Main Circuit: Bars |
Item | Value |
---|---|
Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
General Use Rating UL/CSA | (1000 V DC) 250 A(440 V DC) 250 A(600 V DC) 250 A |
Item | Value |
---|---|
Ambient Air Temperature | Operation -40 ... +80 °CStorage -40 ... +70 °C |
Maximum Operating Altitude Permissible | Without Derating 3000 m |
Resistance to Shock acc. to IEC 60068-2-27 | Shock Direction: A 5 gShock Direction: B1 5 gShock Direction: B2 5 gShock Direction: C1 5 gShock Direction: C2 5 g |
RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Item | Value |
---|---|
Object Classification Code | Q |
ETIM 4 | EC002552 - Power contactor, DC switching |
ETIM 5 | EC002552 - Power contactor, DC switching |
eClass | V11.0 : 27371018 |
IDEA Granular Category Code (IGCC) | 4763 >> Power contactor, DC switching |