1SDA067392R1 - XT1C 160 TMD 32-450 3p F F
by ABB
Original price
$145.14
-
Original price
$145.14
Original price
$145.14
$145.14
-
$145.14
Current price
$145.14
C.BREAKER TMAX XT1C 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 32-450 A
Item | Value |
---|---|
ABB EcoSolutions | Yes |
Item | Value |
---|---|
Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 60.9 % |
Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
End of Life Instructions | 9AKK108468A2347 |
Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
Item | Value |
---|---|
Environmental Product Declaration - EPD | 9AKK108468A1890 |
Item | Value |
---|---|
Environmental Information | 9AKK107991A8215 9AKK108467A6707 |
REACH Declaration | 9AKK108466A1425 |
RoHS Information | 9AKK108466A1424 |
RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Item | Value |
---|---|
Order Code US and Canada | XT1CE3032AFF000XXX |
E-Number (Finland) | 3638774 |
Minimum Order Quantity | 1 piece |
Customs Tariff Number | 85362090 |
Item | Value |
---|---|
Product Net Width | 76.2 mm |
Product Net Height | 130 mm |
Product Net Depth / Length | 70 mm |
Product Net Weight | 1.1 kg |
Item | Value |
---|---|
Circuit Breaker Type to be Associated | Power Distribution |
Connecting Capacity Main Circuit | Busbar 45.5 ... 80 mm² |
Current Type | AC/DC |
Electrical Durability | 120 cycles per hour8000 cycle |
Mechanical Durability | 240 cycles per hour25000 cycle |
Number of Poles | 3 |
Opening Time | CB with SOR 15 msCB with UVR 15 ms |
Order Multiple | 1 piece |
Power Loss | at Rated Operating Conditions per Pole 2.1 W |
Product Main Type | SACE Tmax XT |
Product Name | Moulded Case Circuit Breaker |
Product Type | Automatic Circuit Breaker |
Rated Current (In) | 32 A |
Rated Frequency (f) | 50 / 60 Hz |
Rated Voltage (Ur) | 690 V |
Rated Impulse Withstand Voltage (Uimp) | 8 kV |
Rated Instantaneous Short-Circuit Current Setting (Ii) | 450 A |
Rated Insulation Voltage (Ui) | 800 V |
Rated Operational Voltage | 690 V AC500 V DC |
Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 40 kA(230 V AC) 40 kA(240 V AC) 40 kA(380 V AC) 25 kA(415 V AC) 25 kA(440 V AC) 12.5 kA(500 V AC) 9 kA(525 V AC) 8 kA(690 V AC) 4 kA(250 V DC) 2 Poles in Series 25 kA(500 V DC) 3 Poles in Series 25 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 40 kA(230 V AC) 40 kA(240 V AC) 40 kA(380 V AC) 25 kA(415 V AC) 25 kA(440 V AC) 25 kA(500 V AC) 18 kA(525 V AC) 8 kA(690 V AC) 4 kA(250 V DC) 2 Poles in Series 25 kA(500 V DC) 3 Poles in Series 25 kA |
Rated Uninterrupted Current (Iu) | 160 A |
Recommended Screw Driver | Main Circuit M6 |
Release | TMD |
Release Type | TM |
RoHS Date | NA |
Setting Range | 22.4...32 A |
Short-Circuit Performance Level | C |
Standards | IEC |
Sub-type | XT1 |
Terminal Connection Type | Front |
Terminal Type | Bolt |
Tightening Torque | 6 N·m |
Version | F |
CAD Dimensional Drawing | 1SDH001295R0008 |
Item | Value |
---|---|
ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
Object Classification Code | Q |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
eClass | V11.1 : 27370409 |