1SDA067093R1 - XT2N 160 Ekip LS/I In=100A 4p F F
by ABB
Original price
$482.50
-
Original price
$482.50
Original price
$482.50
$482.50
-
$482.50
Current price
$482.50
C.BREAKER TMAX XT2N 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LS/I R 100 A
Item | Value |
---|---|
ABB EcoSolutions | Yes |
Item | Value |
---|---|
Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 58.1 % |
Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
End of Life Instructions | 9AKK108468A2349 |
Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
Item | Value |
---|---|
Environmental Product Declaration - EPD | 9AKK108468A1897 |
Item | Value |
---|---|
Environmental Information | 9AKK107991A8215 9AKK108467A6707 |
REACH Declaration | 9AKK108466A1425 |
RoHS Information | 9AKK108466A1424 |
RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
SCIP | 1609eb08-e8c3-49f6-a890-5962b956c26a Italy (IT) |
Simplified SCIP | 3279b360-ceb2-40ea-b5b8-ad72e423bb05 Spain (ES)6ac6f831-68c4-4551-866e-5ed081f7a07c Netherlands (NL)4a89c54b-032f-44b5-8c8d-7d0cd35d046d France (FR)dc15b3fa-19b5-4923-89a3-4f384f029b96 Norway (NO)9c25bb52-db28-4e2a-be76-f41b92ffcb96 Finland (FI)bbeb138e-7cf5-43cb-8bbd-f9e0719d5446 Netherlands (NL)e961004c-4e95-4d96-8754-18691fa102c8 Germany (DE)a1af2075-79ed-4e69-8dec-d7d01a11d005 Denmark (DK)42f7f0f4-82fb-4da9-b6b4-dac9338df2b5 Germany (DE)70f63eea-c99f-4c68-915d-74403104364f Croatia (HR)0a736fed-59fb-4cff-b7ba-d7e241a4a7e6 Czech Republic (CZ)bc2c2cd5-113a-4784-b74f-4cf636b4422f Poland (PL)40f41cc1-1b98-417a-bb07-243fb7c3fe3f Netherlands (NL)ebb38ec1-7540-4385-afe0-3f267dc7206b Netherlands (NL)fb7779a5-51b6-4c0f-aa58-396fa1050337 Estonia (EE)221148f9-5cc5-42e4-88bf-d791d508f5c6 Greece (GR)d6c079cf-0aac-4ee2-af23-f75ebd1e4551 Portugal (PT)9536aa0e-b9f0-4044-ba23-d6dafab7e594 Bulgaria (BG)30f517d9-e24a-482d-9248-71ee1fe24992 Sweden (SE)4a15787d-6911-41b5-ba3c-dfa454f63944 Germany (DE)8c818d40-0b99-43a8-b304-fd0f4d823bb2 Poland (PL)bbad2d35-7d33-4dd1-b173-bb90a75acec2 Poland (PL)550fd77c-2475-483b-9e56-8478c5380788 Sweden (SE)4678f95a-3f6c-4fb5-a749-2dc77f54a61e Germany (DE)26238bc6-eb5c-4e9b-adf4-ff0acc6286b7 France (FR)37e16bd4-4f1f-4945-8881-a4cbedaa4ae6 Netherlands (NL) |
Item | Value |
---|---|
Order Code US and Canada | XT2NE4100EFF000XXX |
E-Number (Finland) | 3640566 |
E-Number (Sweden) | 3182034 |
Minimum Order Quantity | 1 piece |
Customs Tariff Number | 85362090 |
Item | Value |
---|---|
Product Net Width | 120 mm |
Product Net Height | 130 mm |
Product Net Depth / Length | 82.5 mm |
Product Net Weight | 1.6 kg |
Item | Value |
---|---|
Circuit Breaker Type to be Associated | Power Distribution |
Connecting Capacity Main Circuit | Busbar 32.5..100 mm² |
Current Type | AC |
Electrical Durability | 120 cycles per hour8000 cycle |
Mechanical Durability | 240 cycles per hour25000 cycle |
Number of Poles | 4 |
Opening Time | CB with SOR 15 msCB with UVR 15 ms |
Order Multiple | 1 piece |
Power Loss | at Rated Operating Conditions per Pole 4.2 W |
Product Main Type | SACE Tmax XT |
Product Name | Moulded Case Circuit Breaker |
Product Type | Automatic Circuit Breaker |
Rated Current (In) | 100 A |
Rated Frequency (f) | 50 / 60 Hz |
Rated Voltage (Ur) | 690 V |
Rated Impulse Withstand Voltage (Uimp) | 8 kV |
Rated Insulation Voltage (Ui) | 1000 V |
Rated Operational Voltage | 690 V AC |
Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA(230 V AC) 65 kA(240 V AC) 65 kA(380 V AC) 36 kA(415 V AC) 36 kA(440 V AC) 36 kA(500 V AC) 30 kA(525 V AC) 20 kA(690 V AC) 10 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA(230 V AC) 65 kA(240 V AC) 65 kA(380 V AC) 36 kA(415 V AC) 36 kA(440 V AC) 36 kA(500 V AC) 30 kA(525 V AC) 20 kA(690 V AC) 10 kA |
Rated Uninterrupted Current (Iu) | 160 A |
Recommended Screw Driver | Main Circuit M6 |
Release | Ekip LS/I |
Release Type | EL |
RoHS Date | NA |
Short-Circuit Performance Level | N |
Standards | IEC |
Sub-type | XT2 |
Terminal Connection Type | Front |
Terminal Type | Bolt |
Tightening Torque | 6 N·m |
Version | F |
CAD Dimensional Drawing | 1SDH002230A1002 |
Item | Value |
---|---|
ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
Object Classification Code | Q |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
eClass | V11.1 : 27370409 |
No Links Available.