Skip to content

1SBL397201R1200 - AF80-40-00-12 48-130V50/60HZ-DC Contactor

by ABB
Original price $323.91 - Original price $323.91
Original price
$323.91
$323.91 - $323.91
Current price $323.91

The AF80-40-00-12 is a 4 pole - 1000 V IEC or 600 UL contactor with screw terminals, controlling motors up to 37 kW / 400 V AC (AC-3) and switching power circuits up to 125 A (AC-1) or 105 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.



Ordering
Item Value
Minimum Order Quantity 1 piece
Customs Tariff Number 85364900

Dimensions
Item Value
Product Net Width 90 mm
Product Net Depth / Length 116 mm
Product Net Height 125.5 mm
Product Net Weight 1.49 kg

Technical
Item Value
Number of Main Contacts NO 4
Number of Main Contacts NC 0
Number of Auxiliary Contacts NO 0
Number of Auxiliary Contacts NC 0
Standards IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage Main Circuit 1000 V
Rated Frequency (f) Control Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie) (690 V) 40 °C 125 A(690 V) 60 °C 105 A(690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie) (415 V) 60 °C 80 A(440 V) 60 °C 80 A(500 V) 60 °C 65 A(690 V) 60 °C 49 A(1000 V) 60 °C 25 A(380 / 400 V) 60 °C 80 A(220 / 230 / 240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe) (415 V) 45 kW(440 V) 45 kW(500 V) 45 kW(690 V) 45 kW(1000 V) 35 kW(380 / 400 V) 37 kW(220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Maximum Breaking Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Maximum Electrical Switching Frequency (AC-1) 600 cycles per hour
Rated Insulation Voltage (Ui) acc. to IEC 60947-4-1 1000 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp) 8 kV
Maximum Mechanical Switching Frequency 3600 cycles per hour
Rated Control Circuit Voltage (Uc) 50 Hz 48 ... 130 V60 Hz 48 ... 130 VDC Operation 48 ... 130 V
Coil Consumption Average Holding Value 50 / 60 Hz 4 V·AAverage Holding Value 50 Hz 4 V·AAverage Holding Value 60 Hz 4 V·AAverage Holding Value DC 2 WAverage Holding Value, from Warm State 2 W
Mounting on DIN Rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit Flexible with Ferrule 1/2x 6 ... 50 mm²Flexible with Insulated Ferrule 1/2x 6 ... 50 mm²Rigid Stranded 1x 6 ... 70 mm²Rigid Stranded 2x 6 ... 50 mm²
Connecting Capacity Control Circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length Control Circuit 10 mmMain Circuit 17 mm
Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal Type Screw Terminals

Technical UL/CSA
Item Value
Maximum Operating Voltage UL/CSA Main Circuit 600 V
General Use Rating UL/CSA (600 V AC) 105 A
Connecting Capacity Main Circuit UL/CSA Rigid Stranded 1/2x 6-1 AWG
Connecting Capacity Control Circuit UL/CSA Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA Control Circuit 11 in·lbMain Circuit 53 in·lb

Environmental
Item Value
Ambient Air Temperature Close to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible Without Derating 3000 m
Resistance to Vibrations acc. to IEC 60068-2-6 5 ... 300 Hz 3 g Closed position / 2 g Open position
RoHS Status Following EU Directive 2011/65/EU

Classifications
Item Value
Object Classification Code Q
ETIM 4 EC000066 - Magnet contactor, AC-switching
ETIM 5 EC000066 - Magnet contactor, AC-switching
eClass V11.0 : 27371003
IDEA Granular Category Code (IGCC) 4758 >> Iec Contactors
E-Number (Finland) 3707459
E-Number (Sweden) 3210314

No Links Available.