Skip to content

1SFL547102R1111 - AF265-40-11-11 Contactor

by ABB
Original price $1,580.74 - Original price $1,580.74
Original price
$1,580.74
$1,580.74 - $1,580.74
Current price $1,580.74

The AF265-40-11-11 is a 4 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 132 kW / 400 V AC (AC-3) / and switching power circuits up to 400 A (AC-1) or 300 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.



Ordering
Item Value
Minimum Order Quantity 1 piece
Customs Tariff Number 85364900

Dimensions
Item Value
Product Net Width 184.4 mm
Product Net Depth / Length 180 mm
Product Net Height 225 mm
Product Net Weight 5.7 kg

Technical
Item Value
Number of Main Contacts NO 4
Number of Main Contacts NC 0
Number of Auxiliary Contacts NO 1
Number of Auxiliary Contacts NC 1
Rated Operational Voltage Main Circuit 1000 V
Rated Frequency (f) Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A
Rated Operational Current AC-1 (Ie) (1000 V) 40 °C 350 A(1000 V) 60 °C 300 A(1000 V) 70 °C 240 A(690 V) 40 °C 400 A(690 V) 60 °C 350 A(690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie) (415 V) 55 °C 265 A(440 V) 55 °C 265 A(500 V) 55 °C 250 A(690 V) 55 °C 250 A(380 / 400 V) 55 °C 265 A(220 / 230 / 240 V) 55 °C 265
Rated Operational Power AC-3 (Pe) (415 V) 132 kW(440 V) 160 kW(380 / 400 V) 132 kW(220 / 230 / 240 V) 75 kW
Rated Breaking Capacity AC-3 8 x Ie AC-3
Rated Making Capacity AC-3 10 x Ie AC-3
Short-Circuit Protective Devices gG Type Fuses 630 A
Rated Short-time Withstand Current Low Voltage (Icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Maximum Breaking Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3800 A
Maximum Electrical Switching Frequency (AC-1) 300 cycles per hour
Rated Insulation Voltage (Ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp) Main Circuit 8 kV
Mechanical Durability 5 million
Maximum Mechanical Switching Frequency 300 cycles per hour
Coil Operating Limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc) 50 Hz 24 ... 60 V60 Hz 24 ... 60 VDC Operation 20 ... 60 V
Coil Consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 8.5 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 8.5 V·AHolding at Max. Rated Control Circuit Voltage DC 3 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 475 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 475 V·APull-in at Max. Rated Control Circuit Voltage DC 400 W
Operate Time Between Coil De-energization and NO Contact Opening 45 ... 80 msBetween Coil Energization and NO Contact Closing 30 ... 60 ms
Connecting Capacity Main Circuit Flexible 2 x 70 ... 185 mm²Rigid Al-Cable 1 x 185 ... 240 mm²Rigid Cu-Cable 2 x 70 ... 185 mm²
Connecting Capacity Auxiliary Circuit Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²
Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type Main Circuit: Bars

Technical UL/CSA
Item Value
NEMA Size 5
Horsepower Rating NEMA (200 V AC) Three Phase 75 Hp(230 V AC) Three Phase 100 Hp(460 V AC) Three Phase 200 Hp(575 V AC) Three Phase 200 Hp
Maximum Operating Voltage UL/CSA Main Circuit 1000 V
General Use Rating UL/CSA (600 V AC) 300 A
Horsepower Rating UL/CSA (200 ... 208 V AC) Three Phase 40 Hp(200 V AC) Three Phase 75 hp(208 V AC) Three Phase 75 hp(220 ... 240 V AC) Three Phase 40 Hp(220 ... 240 V AC) Three Phase 100 hp(440 ... 480 V AC) Three Phase 100 Hp(440 ... 480 V AC) Three Phase 200 hp(550 ... 600 V AC) Three Phase 125 Hp(550 ... 600 V AC) Three Phase 250 hp

Environmental
Item Value
Ambient Air Temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible Without Derating 3000 m
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Circular Value
Item Value
ABB EcoSolutions Yes
Circular Design Principles Recyclability Rate Design for Closing Resource Loops - Standard EN45555 - 76.3 %
End of Life Instructions 1SFC100112M0001
Group Waste to Landfill Target Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
Improved Resource Efficiency for Customers Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Sustainable Material Content Recycled Metal - 33 %

Eco Transparency
Item Value
Environmental Product Declaration - EPD 1SFC100104D0201

Classifications
Item Value
Object Classification Code Q
ETIM 4 EC000066 - Magnet contactor, AC-switching
ETIM 5 EC000066 - Magnet contactor, AC-switching
eClass V11.0 : 27371003
IDEA Granular Category Code (IGCC) 4758 >> Iec Contactors
E-Number (Finland) 3707220
E-Number (Norway) 4117786
E-Number (Sweden) 3210338

No Links Available.