1SFL427001R1311 - AF116-30-11-13 Contactor

by ABB
Original price $281.62 - Original price $281.62
Original price
$281.62
$281.62 - $281.62
Current price $281.62

The AF116-30-11-13 is a 3 pole - 690 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and double clamp, controlling motors up to 55 kW / 400 V AC (AC-3) or 75 hp / 480 V UL and switching power circuits up to 160 A (AC-1) or 160 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.



Ordering
Item Value
Minimum Order Quantity 1 piece
Customs Tariff Number 85364900

Dimensions
Item Value
Product Net Width 90 mm
Product Net Depth / Length 126 mm
Product Net Height 150 mm
Product Net Weight 1.55 kg

Technical
Item Value
Number of Main Contacts NO 3
Number of Main Contacts NC 0
Number of Auxiliary Contacts NO 1
Number of Auxiliary Contacts NC 1
Rated Operational Voltage Main Circuit 690 V
Rated Frequency (f) Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
Rated Operational Current AC-1 (Ie) (690 V) 40 °C 160 A(690 V) 60 °C 145 A(690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie) (415 V) 55 °C 116 A(440 V) 55 °C 116 A(500 V) 55 °C 110 A(690 V) 55 °C 65 A(380 / 400 V) 55 °C 116 A(220 / 230 / 240 V) 55 °C 116
Rated Operational Current AC-3e (Ie) (415 V) 60 °C 116 A(440 V) 60 °C 116 A(500 V) 60 °C 110 A(690 V) 60 °C 65 A(380 / 400 V) 60 °C 116 A(220 / 230 / 240 V) 60 °C 116 A
Rated Operational Power AC-3 (Pe) (415 V) 55 kW(440 V) 75 kW(500 V) 75 kW(690 V) 55 kW(380 / 400 V) 55 kW(220 / 230 / 240 V) 30 kW
Rated Operational Power AC-3e (Pe) (415 V) 55 kW(440 V) 75 kW(500 V) 75 kW(690 V) 55 kW(380 / 400 V) 55 kW(220 / 230 / 240 V) 30 kW
Rated Breaking Capacity AC-3 8 x Ie AC-3
Rated Breaking Capacity AC-3e 8.5 x Ie AC-3e
Rated Making Capacity AC-3 10 x Ie AC-3
Rated Making Capacity AC-3e 12 x Ie AC-3e
Short-Circuit Protective Devices gG Type Fuses 250 A
Rated Short-time Withstand Current Low Voltage (Icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1160 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
Maximum Breaking Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1000 A
Maximum Electrical Switching Frequency (AC-1) 300 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie) (110 V) 2 Poles in Series, 40 °C 145 A(220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-3 (Ie) (110 V) 2 Poles in Series, 40 °C 145 A(220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-5 (Ie) (110 V) 2 Poles in Series, 40 °C 145 A(220 V) 3 Poles in Series, 40 °C 145 A
Rated Insulation Voltage (Ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp) Main Circuit 8 kV
Mechanical Durability 5 million
Maximum Mechanical Switching Frequency 300 cycles per hour
Coil Operating Limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc) 50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V
Coil Consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 6 V·AHolding at Max. Rated Control Circuit Voltage DC 3 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·APull-in at Max. Rated Control Circuit Voltage DC 135 W
Operate Time Between Coil De-energization and NO Contact Opening 37 ... 47 msBetween Coil Energization and NO Contact Closing 25 ... 55 ms
Connecting Capacity Main Circuit Flexible 2 x 10 ... 70 mm²Rigid Cu-Cable 2 x 10 ... 95 mm²
Connecting Capacity Auxiliary Circuit Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²
Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type Double Clamp

Technical UL/CSA
Item Value
Maximum Operating Voltage UL/CSA Main Circuit 600 V
General Use Rating UL/CSA (600 V AC) 160 A
Horsepower Rating UL/CSA (200 V AC) Three Phase 30 hp(208 V AC) Three Phase 30 hp(220 ... 240 V AC) Three Phase 40 hp(440 ... 480 V AC) Three Phase 75 hp(550 ... 600 V AC) Three Phase 100 hp

Environmental
Item Value
Ambient Air Temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible Without Derating 3000 m
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Circular Value
Item Value
ABB EcoSolutions Yes
Circular Design Principles Recyclability Rate Design for Closing Resource Loops - Standard EN45555 - 87.8 %
End of Life Instructions 1SFC100112M0001
Group Waste to Landfill Target Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
Improved Resource Efficiency for Customers Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Sustainable Material Content Recycled Metal - 37 %

Eco Transparency
Item Value
Environmental Product Declaration - EPD 1SFC100092D0201

Classifications
Item Value
Object Classification Code Q
ETIM 4 EC000066 - Magnet contactor, AC-switching
ETIM 5 EC000066 - Magnet contactor, AC-switching
eClass V11.0 : 27371003
IDEA Granular Category Code (IGCC) 4758 >> Iec Contactors
E-Number (Finland) 3706167
E-Number (Norway) 4117610
E-Number (Sweden) 3210068

No Links Available.