1SFL597001R6911 - AF460-30-11 48-130V 50/60Hz / 48-130V DC Contactor
by ABB
Original price
$1,832.51
-
Original price
$1,832.51
Original price
$1,832.51
$1,832.51
-
$1,832.51
Current price
$1,832.51
The AF460-30-11-69 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 250 kW / 400 V AC (AC-3) or 400 hp / 480 V UL and switching power circuits up to 700 A (AC-1) or 650 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Item | Value |
---|---|
Minimum Order Quantity | 1 piece |
Customs Tariff Number | 85364900 |
Item | Value |
---|---|
Product Net Width | 186 mm |
Product Net Depth / Length | 216 mm |
Product Net Height | 278 mm |
Product Net Weight | 10.6 kg |
Item | Value |
---|---|
Number of Main Contacts NO | 3 |
Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 1 |
Number of Auxiliary Contacts NC | 1 |
Rated Operational Voltage | Main Circuit 1000 V |
Rated Frequency (f) | Main Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 700 A |
Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 700 A(1000 V) 55 °C 600 A(1000 V) 60 °C 600 A(1000 V) 70 °C 480 A(690 V) 40 °C 700 A(690 V) 55 °C 600 A(690 V) 70 °C 480 A |
Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 460 A(440 V) 55 °C 460 A(500 V) 55 °C 460 A(690 V) 55 °C 400 A(1000 V) 55 °C 200 A(380 / 400 V) 55 °C 460 A(220 / 230 / 240 V) 55 °C 460 |
Rated Operational Power AC-3 (Pe) | (415 V) 250 kW(440 V) 250 kW(500 V) 315 kW(690 V) 355 kW(1000 V) 280 kW(380 / 400 V) 250 kW(220 / 230 / 240 V) 132 kW |
Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
Rated Making Capacity AC-3 | 10 x Ie AC-3 |
Short-Circuit Protective Devices | gG Type Fuses 800 A |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 4400 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 840 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2500 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4600 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3100 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4500 A |
Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour(AC-2 / AC-4) 60 cycles per hour(AC-3) 300 cycles per hour |
Rated Operational Current DC-1 (Ie) | (110 V) 1-Pole, 40 °C 700 A(110 V) 2 Poles in Series, 40 °C 700 A(220 V) 3 Poles in Series, 40 °C 700 A(600 V) 3 Poles in Series, 40 °C 700 A |
Rated Operational Current DC-3 (Ie) | (110 V) 1-Pole, 40 °C 700 A(110 V) 2 Poles in Series, 40 °C 700 A(220 V) 3 Poles in Series, 40 °C 700 A(600 V) 3 Poles in Series, 40 °C 700 A |
Rated Operational Current DC-5 (Ie) | (110 V) 1-Pole, 40 °C 700 A(110 V) 2 Poles in Series, 40 °C 700 A(220 V) 3 Poles in Series, 40 °C 700 A(600 V) 3 Poles in Series, 40 °C 700 A |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
Mechanical Durability | 3 million |
Maximum Mechanical Switching Frequency | 300 cycles per hour |
Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
Rated Control Circuit Voltage (Uc) | 50 Hz 48 ... 130 V60 Hz 48 ... 130 VDC Operation 48 ... 130 V |
Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 5 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 1215 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 1215 V·APull-in at Max. Rated Control Circuit Voltage DC 1150 V·A |
Operate Time | Between Coil De-energization and NC Contact Closing 45 ... 55 msBetween Coil De-energization and NO Contact Opening 48 ... 58 msBetween Coil Energization and NC Contact Opening 45 ... 115 msBetween Coil Energization and NO Contact Closing 50 ... 120 ms |
Connecting Capacity Main Circuit | Bar 47 mm²Rigid Al-Cable 2x240 mm²Rigid Cu-Cable 240 mm² |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 1x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 1 x 1 .... 4 mm² |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
Terminal Type | Main Circuit: Bars |
Item | Value |
---|---|
NEMA Size | 6 |
Horsepower Rating NEMA | (200 V AC) Three Phase 150 Hp(230 V AC) Three Phase 200 Hp(460 V AC) Three Phase 400 Hp(575 V AC) Three Phase 400 Hp |
Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
General Use Rating UL/CSA | (600 V AC) 650 A |
Horsepower Rating UL/CSA | (200 V AC) Three Phase 150 hp(208 V AC) Three Phase 150 hp(220 ... 240 V AC) Three Phase 200 hp(440 ... 480 V AC) Three Phase 400 hp(550 ... 600 V AC) Three Phase 500 hp |
Item | Value |
---|---|
Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... 70 °C |
Maximum Operating Altitude Permissible | Without Derating 3000 m |
Resistance to Shock acc. to IEC 60068-2-27 | Shock Direction: A 5 gShock Direction: B1 5 gShock Direction: B2 5 gShock Direction: C1 5 gShock Direction: C2 5 g |
RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Item | Value |
---|---|
ABB EcoSolutions | Yes |
Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 63.1 % |
End of Life Instructions | 1SFC100112M0001 |
Group Waste to Landfill Target | Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility |
Improved Resource Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
Sustainable Material Content | Recycled Metal - 37 % |
Item | Value |
---|---|
Environmental Product Declaration - EPD | 1SFC100105D0201 |
Item | Value |
---|---|
Object Classification Code | Q |
ETIM 4 | EC000066 - Magnet contactor, AC-switching |
ETIM 5 | EC000066 - Magnet contactor, AC-switching |
eClass | V11.0 : 27371003 |
IDEA Granular Category Code (IGCC) | 4758 >> Iec Contactors |
E-Number (Norway) | 4115291 |
E-Number (Sweden) | 3228344 |