1SAM350000R1013 - MS132-20 Manual Motor Starter 16 ... 20 A

by ABB
Original price $64.01 - Original price $64.01
Original price
$64.01
$64.01 - $64.01
Current price $64.01

The MS132-20 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 20.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.



Ordering
Item Value
Minimum Order Quantity 1 piece
Customs Tariff Number 85362010

Dimensions
Item Value
Product Net Width 45 mm
Product Net Height 97.8 mm
Product Net Depth / Length 86.55 mm
Product Net Weight 0.31 kg

Technical
Item Value
Rated Service Short-Circuit Breaking Capacity (Ics) (230 V AC) 100 kA(250 V DC) 3 Poles in Series 10 kA(400 V AC) 100 kA(440 V AC) 30 kA(500 V AC) 20 kA(690 V AC) 3 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (230 V AC) 100 kA(400 V AC) 100 kA(440 V AC) 30 kA(500 V AC) 20 kA(690 V AC) 3 kA
Rated Instantaneous Short-Circuit Current Setting (Ii) 300 A
Setting Range 16 ... 20 A
Rated Operational Power AC-3 (Pe) (400 V) Three Phase 7.5 kW
Rated Operational Power AC-3e (Pe) (400 V) Three Phase 7.5 kW
Rated Operational Voltage Main Circuit 690 V ACMain Circuit 250 V DC
Rated Operational Current (Ie) 20 A
Rated Operational Current AC-3 (Ie) 20 A
Rated Operational Current AC-3e (Ie) 20 A
Rated Operational Current DC-5 (Ie) 20 A
Rated Frequency (f) Main Circuit 50 HzMain Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp) Main Circuit 6 kV
Rated Insulation Voltage (Ui) 690 V
Power Loss at Rated Operating Conditions per Pole 1.5 ... 2.3 W
Number of Poles 3
Conventional Free-air Thermal Current (Ith) Main Circuit 20 A
Degree of Protection Housing IP20Main Circuit Terminals IP10
Pollution Degree 3
Electrical Durability 50000 cycle
Mechanical Durability 100000 cycle
Terminal Type Screw Terminals
Connecting Capacity Main Circuit Flexible with Ferrule 1/2x 0.75 ... 6 mm²Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²Flexible 1/2x 1 ... 2.5 mm²Flexible 1/2x 2.5 ... 6 mm²Rigid 1/2x 1 ... 2.5 mm²Rigid 1/2x 2.5 ... 6 mm²
Tightening Torque Main Circuit 2 N·m
Wire Stripping Length Main Circuit 10 mm
Recommended Screw Driver Pozidriv 2
Mounting Position 1 ... 6
Mounting on DIN Rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance Electrical Conductive Board, Horizontal - Up to 400 V 0 mmElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mmElectrical Conductive Board, Vertical 75 mmOther Device Same Type, Horizontal 0 mmOther Device Same Type, Vertical 150 mm
Actuator Type Rotary Handle
Contact Position Indication ON / OFF / TRIP
Standards IEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1UL 60947-1UL 60947-4-1
Remarks UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx

Technical UL/CSA
Item Value
Short-Circuit Current Rating (SCCR) Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Maximum Operating Voltage UL/CSA Main Circuit 600 V AC
Horsepower Rating UL/CSA (200 V AC) Three Phase 5 Hp(208 V AC) Three Phase 5 Hp(220 ... 240 V AC) Three Phase 5 Hp(440 ... 480 V AC) Three Phase 10 Hp(550 ... 600 V AC) Three Phase 15 Hp
Full Load Amps Motor Use (200 V AC) Three Phase 17.5 A(208 V AC) Three Phase 16.7 A(220 ... 240 V AC) Three Phase 15.2 A(440 ... 480 V AC) Three Phase 14 A(550 ... 600 V AC) Three Phase 17 A
Locked Rotor Amps (200 V AC) Three Phase 105.8 A(208 V AC) Three Phase 102 A(220 ... 240 V AC) Three Phase 92 A(440 ... 480 V AC) Three Phase 81 A(550 ... 600 V AC) Three Phase 93 A
General Use Rating UL/CSA (600 V AC) 20 A
Connecting Capacity Main Circuit UL/CSA Flexible 1/2x 16-8 AWGStranded 1/2x 16-8 AWG
Tightening Torque UL/CSA Main Circuit 18 in·lb

Environmental
Item Value
Ambient Air Temperature Around the Enclosure 0 ... +40 °COperation -25 ... +70 °COperation Compensated -25 ... +60 °CStorage -50 ... +80 °C
Ambient Air Temperature Compensation Yes
Maximum Operating Altitude Permissible 2000 m
Resistance to Shock acc. to IEC 60068-2-27 11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6 5g / 3 ... 150 Hz
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Classifications
Item Value
Object Classification Code F
ETIM 4 EC000074 - Motor protective circuit-breaker
ETIM 5 EC000074 - Motor protective circuit-breaker
eClass V11.0 : 27370401
IDEA Granular Category Code (IGCC) 4731 >> Manual Starters
E-Number (Finland) 3705997
E-Number (Sweden) 3112128