Skip to content

1SFL637001R6911 - AF750-30-11 48-130V 50/60Hz / 48-130V DC Contactor

by ABB
Original price $2,616.96 - Original price $2,616.96
Original price
$2,616.96
$2,616.96 - $2,616.96
Current price $2,616.96

The AF750-30-11-69 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 400 kW / 400 V AC (AC-3) or 600 hp / 480 V UL and switching power circuits up to 1050 A (AC-1) or 900 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.



Ordering
Item Value
Minimum Order Quantity 1 piece
Customs Tariff Number 85364900

Dimensions
Item Value
Product Net Width 210 mm
Product Net Depth / Length 242 mm
Product Net Height 283 mm
Product Net Weight 13.6 kg

Technical
Item Value
Number of Main Contacts NO 3
Number of Main Contacts NC 0
Number of Auxiliary Contacts NO 1
Number of Auxiliary Contacts NC 1
Rated Operational Voltage Main Circuit 1000 V
Rated Frequency (f) Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A
Rated Operational Current AC-1 (Ie) (1000 V) 40 °C 1000 A(1000 V) 55 °C 875 A(1000 V) 70 °C 720 A(690 V) 40 °C 1050 A(690 V) 55 °C 875 A(690 V) 70 °C 720 A
Rated Operational Current AC-3 (Ie) (415 V) 55 °C 750 A(440 V) 55 °C 750 A(500 V) 55 °C 750 A(690 V) 55 °C 650 A(1000 V) 55 °C 300 A(380 / 400 V) 55 °C 750 A(220 / 230 / 240 V) 55 °C 750
Rated Operational Power AC-3 (Pe) (415 V) 425 kW(440 V) 450 kW(500 V) 520 kW(690 V) 600 kW(1000 V) 400 kW(380 / 400 V) 400 kW(220 / 230 / 240 V) 220 kW
Rated Breaking Capacity AC-3 8 x Ie AC-3
Rated Making Capacity AC-3 10 x Ie AC-3
Short-Circuit Protective Devices gG Type Fuses 1000 A
Rated Short-time Withstand Current Low Voltage (Icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A
Maximum Breaking Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
Maximum Electrical Switching Frequency (AC-1) 300 cycles per hour(AC-2 / AC-4) 60 cycles per hour(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie) (110 V) 1-Pole, 40 °C 1050 A(110 V) 2 Poles in Series, 40 °C 1050 A(220 V) 3 Poles in Series, 40 °C 1050 A(600 V) 3 Poles in Series, 40 °C 1050 A(850 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-3 (Ie) (110 V) 1-Pole, 40 °C 1050 A(110 V) 2 Poles in Series, 40 °C 1050 A(220 V) 3 Poles in Series, 40 °C 1050 A(600 V) 3 Poles in Series, 40 °C 1050 A(850 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-5 (Ie) (110 V) 1-Pole, 40 °C 1050 A(110 V) 2 Poles in Series, 40 °C 1050 A(220 V) 3 Poles in Series, 40 °C 1050 A(600 V) 3 Poles in Series, 40 °C 1050 A(850 V) 3 Poles in Series, 40 °C 1050 A
Rated Insulation Voltage (Ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp) Main Circuit 8 kV
Mechanical Durability 3 million
Maximum Mechanical Switching Frequency 300 cycles per hour
Coil Operating Limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc) 50 Hz 48 ... 130 V60 Hz 48 ... 130 VDC Operation 48 ... 130 V
Coil Consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 5 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 1100 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 1100 V·APull-in at Max. Rated Control Circuit Voltage DC 1020 V·A
Operate Time Between Coil De-energization and NC Contact Closing 50 ... 70 msBetween Coil De-energization and NO Contact Opening 53 ... 73 msBetween Coil Energization and NC Contact Opening 45 ... 115 msBetween Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main Circuit Bar 52 mm²Rigid Al-Cable 3x185 mm²Rigid Cu-Cable 300 mm²
Connecting Capacity Auxiliary Circuit Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 1 x 1 .... 4 mm²
Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type Main Circuit: Bars

Technical UL/CSA
Item Value
NEMA Size 7
Horsepower Rating NEMA (230 V AC) Three Phase 300 Hp(460 V AC) Three Phase 600 Hp(575 V AC) Three Phase 600 Hp
Maximum Operating Voltage UL/CSA Main Circuit 1000 V
General Use Rating UL/CSA (1000 V AC) 900 A(600 V AC) 900 A
Horsepower Rating UL/CSA (200 V AC) Three Phase 250 hp(208 V AC) Three Phase 250 hp(220 ... 240 V AC) Three Phase 300 hp(440 ... 480 V AC) Three Phase 600 hp(550 ... 600 V AC) Three Phase 700 hp

Environmental
Item Value
Ambient Air Temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27 Shock Direction: A 5 gShock Direction: B1 5 gShock Direction: B2 5 gShock Direction: C1 5 gShock Direction: C2 5 g
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Classifications
Item Value
Object Classification Code Q
ETIM 4 EC000066 - Magnet contactor, AC-switching
ETIM 5 EC000066 - Magnet contactor, AC-switching
eClass V11.0 : 27371003
IDEA Granular Category Code (IGCC) 4758 >> Iec Contactors
E-Number (Norway) 4115299
E-Number (Sweden) 3228364

No Links Available.