1SBH137001R1340 - NF40E-13 100-250V50/60HZ-DC Contactor Relay
by ABB
Original price
$29.31
-
Original price
$29.31
Original price
$29.31
$29.31
-
$29.31
Current price
$29.31
NF contactor relays are used for switching auxiliary and control circuits. NF contactor relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. NF contactor relays can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. NF contactor relays have built-in surge protection and do not require additional surge suppressors. - Poles: 4-pole contactor relays - Control Circuit: AC or DC operated - Accessories: a wide range of Accessories is available.
Item | Value |
---|---|
Minimum Order Quantity | 1 piece |
Customs Tariff Number | 85364900 |
Item | Value |
---|---|
Product Net Width | 45 mm |
Product Net Depth / Length | 77 mm |
Product Net Height | 86 mm |
Product Net Weight | 0.27 kg |
Item | Value |
---|---|
Number of Auxiliary Contacts NO | 4 |
Number of Auxiliary Contacts NC | 0 |
Standards | IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13 |
Rated Operational Voltage | Auxiliary Circuit 690 V |
Rated Frequency (f) | Auxiliary Circuit 50 / 60 HzControl Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
Rated Operational Current AC-15 (Ie) | (500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(400 / 440 V) 3 A |
Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 140 Afor 1 s 100 A |
Maximum Electrical Switching Frequency | (AC-15) 1200 cycles per hour(DC-13) 900 cycles per hour |
Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(125 V) 0.55 A / 69 W(220 V) 0.27 A / 60 W(250 V) 0.27 A / 68 W(400 V) 0.15 A / 60 W(500 V) 0.13 A / 65 W(600 V) 0.1 A / 60 W |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-5-1 690 Vacc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) | 6 kV |
Maximum Mechanical Switching Frequency | 6000 cycles per hour |
Rated Control Circuit Voltage (Uc) | 50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V |
Operate Time | Between Coil De-energization and NC Contact Closing 13 ... 98 msBetween Coil De-energization and NO Contact Opening 11 ... 95 msBetween Coil Energization and NC Contact Opening 38 ... 90 msBetween Coil Energization and NO Contact Closing 40 ... 95 ms |
Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Mounting by Screws (not supplied) | 2 x M4 screws placed diagonally |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm² |
Wire Stripping Length | Auxiliary Circuit 10 mmControl Circuit 10 mm |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
Terminal Type | Screw Terminals |
Item | Value |
---|---|
Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG |
Tightening Torque UL/CSA | Auxiliary Circuit 11 in·lbControl Circuit 11 in·lb |
Item | Value |
---|---|
Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air -40 ... 70 °C |
Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible | Without Derating 3000 m |
Resistance to Vibrations acc. to IEC 60068-2-6 | 5 ... 300 Hz 4 g closed position / 2 g open position |
Resistance to Shock acc. to IEC 60068-2-27 | Closed, Shock Direction: B1 25 gOpen, Shock Direction: B1 5 gShock Direction: A 30 gShock Direction: B2 15 gShock Direction: C1 25 gShock Direction: C2 25 g |
RoHS Status | Following EU Directive 2011/65/EU |
Item | Value |
---|---|
Object Classification Code | K |
ETIM 4 | EC000196 - Contactor relay |
ETIM 5 | EC000196 - Contactor relay |
eClass | V11.0 : 27371001 |
IDEA Granular Category Code (IGCC) | 4763 >> Power contactor, DC switching |
E-Number (Finland) | 3706415 |
E-Number (Sweden) | 3211456 |
No Links Available.