The AF400-30-11-70 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 200 kW / 400 V AC (AC-3) or 350 hp / 480 V UL and switching power circuits up to 600 A (AC-1) or 550 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.



Ordering
Item Value
Minimum Order Quantity 1 piece
Customs Tariff Number 85364900

Dimensions
Item Value
Product Net Width 186 mm
Product Net Depth / Length 216 mm
Product Net Height 278 mm
Product Net Weight 10.6 kg

Technical
Item Value
Number of Main Contacts NO 3
Number of Main Contacts NC 0
Number of Auxiliary Contacts NO 1
Number of Auxiliary Contacts NC 1
Rated Operational Voltage Main Circuit 1000 V
Rated Frequency (f) Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A
Rated Operational Current AC-1 (Ie) (1000 V) 40 °C 600 A(1000 V) 55 °C 500 A(1000 V) 70 °C 400 A(690 V) 40 °C 600 A(690 V) 55 °C 500 A(690 V) 70 °C 400 A
Rated Operational Current AC-3 (Ie) (415 V) 55 °C 400 A(440 V) 55 °C 400 A(500 V) 55 °C 400 A(690 V) 55 °C 350 A(1000 V) 55 °C 155 A(380 / 400 V) 55 °C 400 A(220 / 230 / 240 V) 55 °C 400
Rated Operational Power AC-3 (Pe) (415 V) 220 kW(440 V) 220 kW(500 V) 250 kW(690 V) 315 kW(1000 V) 220 kW(380 / 400 V) 200 kW(220 / 230 / 240 V) 110 kW
Rated Breaking Capacity AC-3 8 x Ie AC-3
Rated Making Capacity AC-3 10 x Ie AC-3
Short-Circuit Protective Devices gG Type Fuses 630 A
Rated Short-time Withstand Current Low Voltage (Icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 4400 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 840 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2500 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4600 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3100 A
Maximum Breaking Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4000 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3500 A
Maximum Electrical Switching Frequency (AC-1) 300 cycles per hour(AC-2 / AC-4) 60 cycles per hour(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie) (110 V) 1-Pole, 40 °C 600 A(110 V) 2 Poles in Series, 40 °C 600 A(220 V) 3 Poles in Series, 40 °C 600 A(600 V) 3 Poles in Series, 40 °C 600 A
Rated Operational Current DC-3 (Ie) (110 V) 1-Pole, 40 °C 600 A(110 V) 2 Poles in Series, 40 °C 600 A(220 V) 3 Poles in Series, 40 °C 600 A(600 V) 3 Poles in Series, 40 °C 600 A
Rated Operational Current DC-5 (Ie) (110 V) 1-Pole, 40 °C 600 A(110 V) 2 Poles in Series, 40 °C 600 A(220 V) 3 Poles in Series, 40 °C 600 A(600 V) 3 Poles in Series, 40 °C 600 A
Rated Insulation Voltage (Ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp) Main Circuit 8 kV
Mechanical Durability 3 million
Maximum Mechanical Switching Frequency 300 cycles per hour
Coil Operating Limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc) 50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V
Coil Consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 5 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 955 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 955 V·APull-in at Max. Rated Control Circuit Voltage DC 895 V·A
Operate Time Between Coil De-energization and NC Contact Closing 45 ... 55 msBetween Coil De-energization and NO Contact Opening 48 ... 58 msBetween Coil Energization and NC Contact Opening 45 ... 115 msBetween Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main Circuit Bar 47 mm²Rigid Al-Cable 2x240 mm²Rigid Cu-Cable 240 mm²
Connecting Capacity Auxiliary Circuit Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²
Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type Main Circuit: Bars

Technical UL/CSA
Item Value
Maximum Operating Voltage UL/CSA Main Circuit 1000 V
General Use Rating UL/CSA (600 V AC) 550 A
Horsepower Rating UL/CSA (200 V AC) Three Phase 125 hp(208 V AC) Three Phase 125 hp(220 ... 240 V AC) Three Phase 150 hp(440 ... 480 V AC) Three Phase 350 hp(550 ... 600 V AC) Three Phase 400 hp

Environmental
Item Value
Ambient Air Temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27 Shock Direction: A 5 gShock Direction: B1 5 gShock Direction: B2 5 gShock Direction: C1 5 gShock Direction: C2 5 g
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Circular Value
Item Value
ABB EcoSolutions Yes
Circular Design Principles Recyclability Rate Design for Closing Resource Loops - Standard EN45555 - 63.1 %
End of Life Instructions 1SFC100112M0001
Group Waste to Landfill Target Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
Improved Resource Efficiency for Customers Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Sustainable Material Content Recycled Metal - 37 %

Eco Transparency
Item Value
Environmental Product Declaration - EPD 1SFC100105D0201

Classifications
Item Value
Object Classification Code Q
ETIM 4 EC000066 - Magnet contactor, AC-switching
ETIM 5 EC000066 - Magnet contactor, AC-switching
eClass V11.0 : 27371003
IDEA Granular Category Code (IGCC) 4758 >> Iec Contactors
E-Number (Finland) 3709332
E-Number (Norway) 4115288
E-Number (Sweden) 3228336

No Links Available.