1SDA066806R1 - XT1B 160 TMD 80-800 3p F F

by ABB
Original price $143.28 - Original price $143.28
Original price
$143.28
$143.28 - $143.28
Current price $143.28

C.BREAKER TMAX XT1B 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 80-800 A



ABB EcoSolutions
Item Value
ABB EcoSolutions Yes

Circular Value
Item Value
Circular Design Principles Recyclability Rate Design for Closing Resource Loops - Standard EN45555 - 60.9 %
Conflict Minerals Reporting Template (CMRT) 9AKK108467A5658
End of Life Instructions 9AKK108468A2347
Group Waste to Landfill Target UL 2799 Zero Waste To Landfill Validation available
Toxic Substances Control Act - TSCA 9AKK108467A8326

Eco Transparency
Item Value
Environmental Product Declaration - EPD 9AKK108468A1890

Environmental
Item Value
Environmental Information 9AKK107991A8215 9AKK108467A6707
REACH Declaration 9AKK108466A1425
RoHS Information 9AKK108466A1424
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Ordering
Item Value
Order Code US and Canada XT1BE3080AFF000XXX
E-Number (Finland) 3640499
Minimum Order Quantity 1 piece
Customs Tariff Number 85362090

Dimensions
Item Value
Product Net Width 76.2 mm
Product Net Height 130 mm
Product Net Depth / Length 70 mm
Product Net Weight 1.1 kg

Additional Information
Item Value
Circuit Breaker Type to be Associated Power Distribution
Connecting Capacity Main Circuit Busbar 45.5 ... 80 mm²
Current Type AC/DC
Electrical Durability 120 cycles per hour8000 cycle
Mechanical Durability 240 cycles per hour25000 cycle
Number of Poles 3
Opening Time CB with SOR 15 msCB with UVR 15 ms
Order Multiple 1 piece
Power Loss at Rated Operating Conditions per Pole 4.8 W
Product Main Type SACE Tmax XT
Product Name Moulded Case Circuit Breaker
Product Type Automatic Circuit Breaker
Rated Current (In) 80 A
Rated Frequency (f) 50 / 60 Hz
Rated Voltage (Ur) 690 V
Rated Impulse Withstand Voltage (Uimp) 8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii) 800 A
Rated Insulation Voltage (Ui) 800 V
Rated Operational Voltage 690 V AC500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics) (220 V AC) 25 kA(230 V AC) 25 kA(240 V AC) 25 kA(380 V AC) 18 kA(415 V AC) 18 kA(440 V AC) 11.25 kA(500 V AC) 8 kA(525 V AC) 6 kA(690 V AC) 3 kA(250 V DC) 2 Poles in Series 18 kA(500 V DC) 3 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (220 V AC) 25 kA(230 V AC) 25 kA(240 V AC) 25 kA(380 V AC) 18 kA(415 V AC) 18 kA(440 V AC) 15 kA(500 V AC) 8 kA(525 V AC) 6 kA(690 V AC) 3 kA(250 V DC) 2 Poles in Series 18 kA(500 V DC) 3 Poles in Series 18 kA
Rated Uninterrupted Current (Iu) 160 A
Recommended Screw Driver Main Circuit M6
Release TMD
Release Type TM
RoHS Date NA
Setting Range 56...80 A
Short-Circuit Performance Level B
Standards IEC
Sub-type XT1
Terminal Connection Type Front
Terminal Type Bolt
Tightening Torque 6 N·m
Version F
CAD Dimensional Drawing 1SDH001295R0008

Classifications
Item Value
ETIM 9 EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code Q
WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)
eClass V11.1 : 27370409