3RA2130-4KA38-0NB3 - L. FEEDER DS 100KA S2, 62-65A, 20-33VACDC
by Siemens
Original price
$693.39
-
Original price
$693.39
Original price
$693.39
$693.39
-
$693.39
Current price
$693.39
Load feeder fuseless, Direct-on-line starting 400 V AC, Size S2 62 ... 65 A 20 ... 33 V AC/DC screw terminal for installation on standard mounting rail (also fulfills type of coordination 1) Type of coordination 2, Iq = 100 kA 1 NO+1 NC (contactor) with circuit (integrated)
Item | Value |
---|---|
Country of Origin | DE |
Width | 55 mm |
Depth | 150 mm |
Height | 274 mm |
With fuse | false |
Release class | CLASS 10 |
With transformer | false |
Kind of motor starter | Other |
Rail mounting possible | true |
Number of indicator lights | 0 |
External reset possible | false |
Number of command positions | 1 |
Degree of protection (IP) | IP20 |
Rated operation current Ie | 73 A |
With short-circuit release | true |
Suitable for emergency stop | true |
Voltage type for actuating | AC/DC |
Degree of protection (NEMA) | Other |
Supporting protocol for ASI | false |
Supporting protocol for CAN | false |
Supporting protocol for LON | false |
Overload release current setting | 62 A |
Supporting protocol for MODBUS | false |
Supporting protocol for SERCOS | false |
Supporting protocol for TCP/IP | false |
Supporting protocol for SUCONET | false |
Supporting protocol for INTERBUS | false |
Supporting protocol for PROFIBUS | false |
Supporting protocol for DeviceNet | false |
Supporting protocol for PROFIsafe | false |
Rated control supply voltage Us at DC | 20 V |
Rated operation power at AC-3, 400 V | 37 kW |
Supporting protocol for EtherNet/IP | false |
Supporting protocol for PROFINET IO | false |
Supporting protocol for SafetyBUS p | false |
Rated operation current at AC-3, 400 V | 73 A |
Supporting protocol for Data-Highway | false |
Supporting protocol for PROFINET CBA | false |
Supporting protocol for INTERBUS-Safety | false |
Rated control supply voltage Us at AC 50HZ | 20 V |
Rated control supply voltage Us at AC 60HZ | 20 V |
Supporting protocol for DeviceNet Safety | false |
Supporting protocol for other bus systems | false |
Temperature compensated overload protection | true |
Supporting protocol for Foundation Fieldbus | false |
Ambient temperature, upper operating limit | 60 °C |
Coordination class according to IEC 60947-4-3 | Class 2 |
Supporting protocol for AS-Interface Safety at Work | false |
Rated conditional short-circuit current, type 2, 230 V | 100000 A |
Rated conditional short-circuit current, type 2, 400 V | 100000 A |
Type of electrical connection of main circuit | Screw connection |
Rated conditional short-circuit current, type 1, 480 Y/277 V | 20000 A |