A 3-pole Contactor suitable for DC-1 applications where all three poles must be connected in series in a 1-pole configuration up to max 1000 VDC. Operated with wide control voltage range 100-250 V, AC/DC



Ordering
Item Value
Minimum Order Quantity 1 piece
Customs Tariff Number 85364900

Dimensions
Item Value
Product Net Width 438 mm
Product Net Depth / Length 244 mm
Product Net Height 392 mm
Product Net Weight 33 kg

Technical
Item Value
Number of Main Contacts NO 1
Number of Main Contacts NC 0
Number of Auxiliary Contacts NO 1
Number of Auxiliary Contacts NC 1
Rated Operational Voltage Main Circuit 1000 V
Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 2050 A
Rated Operational Current DC-1 (Ie) (1000 V) 3 Poles in Series, 40 °C 2050 A(1000 V) 3 Poles in Series, 55 °C 1750 A(1000 V) 3 Poles in Series, 70 °C 1500 A(220 V) 3 Poles in Series, 40 °C 2050 A(220 V) 3 Poles in Series, 55 °C 1750 A(220 V) 3 Poles in Series, 70 °C 1500 A(400 V) 3 Poles in Series, 40 °C 2050 A(400 V) 3 Poles in Series, 55 °C 1750 A(400 V) 3 Poles in Series, 70 °C 1500 A(600 V) 3 Poles in Series, 40 °C 2050 A(600 V) 3 Poles in Series, 55 °C 1750 A(600 V) 3 Poles in Series, 70 °C 1500 A
Rated Insulation Voltage (Ui) acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp) Main Circuit 8 kV
Mechanical Durability 0.5 million
Maximum Mechanical Switching Frequency 300 cycles per hour
Coil Operating Limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc) 50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V
Coil Consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 48 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 48 V·AHolding at Max. Rated Control Circuit Voltage DC 16 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 1900 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 1900 V·APull-in at Max. Rated Control Circuit Voltage DC 1700 V·A
Connecting Capacity Main Circuit Bar 100 mm²
Connecting Capacity Auxiliary Circuit Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²
Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type Main Circuit: Bars

Technical UL/CSA
Item Value
Maximum Operating Voltage UL/CSA Main Circuit 600 V
General Use Rating UL/CSA (1000 V DC) 2050 A(440 V DC) 2050 A(600 V DC) 2050 A

Environmental
Item Value
Ambient Air Temperature Operation -40 ... +80 °CStorage -40 ... +70 °C
Maximum Operating Altitude Permissible Without Derating 3000 m
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Classifications
Item Value
Object Classification Code Q
ETIM 4 EC002552 - Power contactor, DC switching
ETIM 5 EC002552 - Power contactor, DC switching
eClass V11.0 : 27371018
IDEA Granular Category Code (IGCC) 4763 >> Power contactor, DC switching