Skip to content

1SFA898115R7000 - PSTX370-600-70 Softstarter - 370 A - 208 ... 600 V AC

by ABB
Original price $6,218.63 - Original price $6,218.63
Original price
$6,218.63
$6,218.63 - $6,218.63
Current price $6,218.63

The softstarter PSTX370-600-70 has a rated maximum operational current of 370 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard.To interact with PSTX, it has a detachable full graphic display with IP66 and 4x outdoor rating. There are four ways to communicate with PSTX. It can be done by hardwire inputs Start/Stop/Reset of fault, and by three programmable digital inputs. Another popular option is the built-in Fieldbus communication Modbus RTU and incl optional ANYBUS modules with every major protocol such as for example Profinet, Profibus, Modbus TCP, Ethernet IP and others. Another way to communicate with PSTX is to use an external adaptor and a Fieldbus plug. PSTX is the complete alternative for any motor starting application. It’s suitable for medium to large-sized three-phase motors with nominal currents from 30...1250 A inline connection or 52...2160 A inside delta connection. Typical applications are, for example, pumps, fans, compressors, and conveyors.



Ordering
Item Value
Minimum Order Quantity 1 piece
Customs Tariff Number 85371091

Dimensions
Item Value
Product Net Width 258 mm
Product Net Height 470 mm
Product Net Depth / Length 279 mm
Product Net Weight 15.5 kg

Technical
Item Value
Rated Operational Voltage 208 ... 600 V AC
Rated Control Supply Voltage (Us) 100 ... 250 V AC
Rated Control Circuit Voltage (Uc) 24 V DC
Rated Frequency (f) 50/60 HzMain Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe) (230 V) 110 kW(400 V) 200 kW(500 V) 257 kW
Rated Operational Current - In-Line Connection (Ie) 370 A
Rated Operational Power - Inside Delta Connection at 230 V 200 kWat 400 V 355 kWat 500 V 450 kW
Rated Operational Current - Inside Delta Connection 640 A
Service Factor Percentage 100 %
Overload Protection Built-in electronic overload protection
Integrated Electronic Overload Yes
Adjustable Rated Motor Current Ie 30 ... 100 %
Starting Capacity at Maximum Rated Current Ie 4xIe for 10s
Ramp Time 1 ... 120 second [unit of time]
Initial Voltage During Start 10 ... 99 %
Step Down Voltage Special Ramp 100 ... 10 %
Current Limit Function 1.5 ... 7.5 xle
Switch for Inside Delta Connection Yes
Run Signal Relay Yes
By-pass Signal Relay Yes
Fault Signal Relay Yes
Overload Signal Relay Yes
Analog Outputs 0…10 V, 0…20 mA, 4…20 mA
Signal Indication Ready to Start/Standby ON (LED) Green
Signal Indication Running R (LED) Green
Signal Indication Protection (LED) Yellow
Signal Indication Fault (LED) Red
Communication Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of Protection IP00
Terminal Type Main Circuit: Bars
Connecting Capacity Main Circuit Hole Diameter 8.5 mm
Connecting Capacity Control Circuit Rigid 1 x 2.5 mm²
Connecting Capacity Supply Circuit Rigid 1 x 2.5 mm²
Tightening Torque Main Circuit 25 N·m
Product Main Type PSTX370
Function Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logFull voltage startJog with slow speed, forward and reverseKeypad passwordKick startLimp mode with two-phase motor control if one set of thyristors is shortedMotor heatingPre-start functionPump cleaningReal time clockSequence startSoft start with torque controlSoft start with voltage rampSoft stop with torque controlSoft stop with voltage rampStand still brakeStart reverse (external contactors)Thyristor runtime measurementTorque limitVoltage sags detection
Protection Function Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning Details Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Technical UL/CSA
Item Value
Maximum Operating Voltage UL/CSA Main Circuit 600 V
Tightening Torque UL/CSA Main Circuit 221.3

Environmental
Item Value
Ambient Air Temperature Operation -25 ... +60 °CStorage -40 ... +70 °C
Degree of Protection IP00
RoHS Status Following EU Directive 2002/95/EC August 18, 2005 and amendment

Classifications
Item Value
Object Classification Code Q
ETIM 9 EC000640 - Soft starter
eClass V11.0 : 27370907
IDEA Granular Category Code (IGCC) 4740 >> Soft starter

No Links Available.